Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Slaughterhouse & Feed Mill Automated Vehicle Biosecurity
S04 · Abattoir & Feed Mill Supply Chain

Slaughterhouse Truck Wash System & Feed Bays

Slaughterhouse docks and bulk feed fleets cross dozens of farms weekly. Strip fat at 80–100°C, dose 316L chemicals automatically, and dry before loading.

80–100°C120 L/min Fat & Blood Wash
20 MPa Arch<4,200 mm Touchless Gantry
316L RS485Auto Foam & Virucide Switch
700–800 kWDry Feed-Truck Dispatch
Biosecurity Solution

Stop Docks and Feed Mills Spreading Pathogens

BioFortis slaughterhouse truck wash system and feed mill bays combine 120 kW 80–100°C hot-water boilers (0–120 L/min), 20 MPa touchless gantries, IP67 chassis washers, 316L RS485 chemical switching, and 700–800 kW thermal drying for continuous shifts.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
80–100°CAbattoir Lipid Emulsification
0–120 L/minNatural Gas Peak Hot Flow
<4,200 mmFeed Tanker & Rig Clearance
0% MoistureMold-Free Feed Dispatch
4-Stage System Lineup

Four Stages Built for Continuous Shifts

Strip coagulated blood lipids quickly and leave bulk feed tankers completely dry before pellet loading.

Stage 1 · 80–100°C 120 kW Natural Gas / Diesel Boiler

120 kW Natural Gas / Diesel Boiler

Instant-heating 0–30 MPa coils deliver up to 120 L/min at 80–100°C to dissolve coagulated blood and abattoir lipids rapidly.

120 kW | 0–120 L/min | 0–30 MPa | 100°C

View P10 Gas Boiler
Stage 2 · Touchless Arch 20 MPa Touchless Exterior Gantry

20 MPa Touchless Exterior Gantry

4.2 m clearance full anti-corrosion arch sanitizes bulk feed tankers and live-haul rigs cleanly without brush cross-contamination.

20 MPa | 120 L/min | <4,200 mm | 4.22 kW

View P02 Exterior Gantry
Stage 3 · Undercarriage IP67 Automated Chassis Washer

IP67 Automated Chassis Washer

15–20 MPa / 60 L/min 360° rotating nozzles with waterproof 0.37 kW drive and SS drag chain strip dock mud and blood runoff.

15–20 MPa | 60 L/min | IP67 | SS Drag Chain

View P03 Chassis Wash
Stage 4 · 316L Dosing RS485 High-Pressure Chemical Switching

RS485 High-Pressure Chemical Switching

0.5–10 MPa (custom 25 MPa) 316L/PTFE medicator swaps automatically between alkaline foaming degreaser and virucidal disinfectant.

±1% | 316L SS/PTFE | RS485 Modbus RTU

View P13 High-Pressure Doser
How It Works

Hot Degreasing, Zero Brushes & Dry Tankers

120 L/min Hot Water Dissolves Blood & Fat

120 L/min Hot Water Dissolves Blood & Fat

Cold water solidifies animal fat on rendering rigs and leaves protective biofilm over pathogens. P10 120 kW natural gas boilers and P09 diesel units heat water downstream to 80–100°C on demand.

0–120 L/minMulti-Arch Gas Flow
80–100°CRapid Blood/Fat Strip
Touchless Gantry + Automated 316L Dosing

Touchless Gantry + Automated 316L Dosing

Rollover brushes drag abattoir blood directly onto the next clean truck. P02 anti-corrosion gantries, P03 IP67 chassis washers, and P13 316L RS485 medicators swap from alkaline degreaser foam to virucide automatically.

±1% Accuracy316L RS485 Proportioning
IP67 DriveBlood/Splash Trench Safe
Dry Feed Tankers Before Loading Pellets

Dry Feed Tankers Before Loading Pellets

Loading dry feed into damp wheel arches or augers triggers clumping and mold claims downstream. P05 700–800 kW drying bays clear moisture in 30–45 minutes while 65°C P23 hand stations isolate drivers.

30–45 minRapid Moisture Removal
65°C P23Driver Entry Hygiene
System Layout

Four Continuous-Duty Bay Modules

120 kW 0–30 MPa Instant Boiler

Natural gas (0–120 L/min) or diesel (0–30 L/min) coil heats pressurized wash water to 80–100°C on demand.

4.2 m Touchless Gantry & IP67 Chassis

Corrosion-treated arch and waterproof undercarriage trolley handle live-haul trailers and bulk feed tankers.

Slaughterhouse & Feed Mill Automated Vehicle Biosecurity structural breakdown
316L RS485 Dual-Chemical Dosing

Injects alkaline degreaser foam and virucidal disinfectant downstream of main pumps with SCADA logging.

700–800 kW Dryer & Driver Hygiene

Eliminates residual moisture before feed loading while P23 heated hand stations block driver cross-transfer.

Upgrading an Abattoir or Feed Mill Bay? Tell us your daily truck count and gas/diesel utilities for a continuous-shift CAD layout and quote in 12 hours.
Technical Specifications

Abattoir vs. Feed Mill Specifications

Side-by-side BioFortis system configurations tailored for heavy abattoir grease versus moisture-sensitive bulk feed fleets.

ParameterSpecificationNote
Abattoir / Rendering Wash Temp85–100°C | P10 Natural Gas (0–120 L/min)Dissolves coagulated blood & heavy fat rapidly; P09 diesel off-grid
Bulk Feed Mill Wash Temp60–80°C | P09/P10/P11 120 kW BoilerCuts road grime & feed dust without stressing tanker seals
Exterior & Chassis ModulesP02 Gantry (<4.2 m) + P03 IP67 Chassis20 MPa / 120 L/min touchless arch + 60 L/min rotating underbody
Automated Chemical SwitchingP13 316L SS / PTFE (0.5–10/25 MPa)±1% accuracy; RS485 Modbus RTU; alkaline foam -> virucide
Thermal Drying & TurnaroundP05 700–800 kW (<14 m) | 30–45 minPrevents feed moisture clumping & delivers 70°C+ viral kill
Driver & Dock Hygiene BarrierP23 Automatic Heated Two-Hand StationAC 380V, 2 kW heater, 9 L/min @ 65°C between dock & clean zone
Sizing & Site Prep

Plan Bay Flow, Fuel & Maintenance

Interactive Engineering Tool

Truck Wash & Thermal Drying Hub Sizing Calculator

Estimate required wash lanes, 700–800 kW drying chambers, daily water demand, and 380V electrical load for your biosecurity center.

Recommended Wash Bays (20 MPa)--
Recommended Drying Rooms--
Estimated Wash Water Demand--
Estimated Connected Load--
“Cleaning trucks leaving an abattoir dock or feed mill protects every partner sow farm down the road.”
BioFortis Supply-Chain Biosecurity · Abattoir, Rendering & Feed Mill Standard
Common Field Problems

Four Dock & Feed Wash Pitfalls Solved

Field Problem

Cold Water Congealing Blood & Fat

How BioFortis Solves It

120 kW natural gas or diesel boilers deliver 80–100°C pressurized hot water downstream of main pumps.

Field Problem

Damp Feed Tankers Triggering Mold Claims

How BioFortis Solves It

700–800 kW drying rooms remove all moisture in 30–45 minutes ahead of bulk pellet loading.

Field Problem

Brush Rollovers Dragging Blood Between Rigs

How BioFortis Solves It

Touchless 20 MPa arches and IP67 underbody rotating jets leave zero brush contact.

Field Problem

Caustic Cleaners Wrecking Pump Plungers

How BioFortis Solves It

316L/PTFE injectors dose strictly downstream at ±1% accuracy with Modbus tracking.

Delivery Process

Five Steps to High-Volume Commissioning

01

Shift Volume & Fuel Audit

Assess daily truck peaks, live-haul vs tanker heights, and piped gas/diesel utilities.

Day 1–2
02

Grease-Trap & Bay CAD

Deliver drive-through traffic, grease interceptor trench, flue, and 380V schematics.

Day 3–7
03

20 MPa, 100°C & RS485 FAT

Test full-pressure skids, hot-water coils, and 316L dosing accuracy prior to crating.

Week 3–6
04

Export Container Packing

Ship modular gantry, boiler, chassis, drying, and 12-month continuous-shift spare kits.

Week 6–7
05

Commissioning & SCADA Link

Complete on-site/remote startup, Modbus telemetry integration, and shift SOP training.

On-Site
Field-Proven on Continuous Commercial Shifts
Field Track Record

Field-Proven on Continuous Commercial Shifts

BioFortis 20 MPa touchless gantries, stainless pump skids, and 700–800 kW thermal drying rooms run multi-shift swine transport schedules across 3 sites in Vietnam and 4 repeat drying bays in Perak, Malaysia.

Testing & Export Docs

FAT Sheets, Grease Trench CAD & Modbus Maps

DOC-01

Pressure, Thermal & Dosing FAT

Factory test sheets verifying 20 MPa output, 100°C coil firing, and ±1% dosing accuracy.

Included
DOC-02

Grease Trench, Flue & 380V CAD

DWG/PDF civil drainage, gas/diesel flue exhaust, and electrical wiring drawings.

Included
DOC-03

English Shift SOP & Modbus Map

Two-shift operator manuals, chemical changeover guides, and RS485 SCADA register tables.

Included
DOC-04

Customs & Continuous-Duty BOM

Export invoices, HS codes, and 12-month high-wear seals, nozzles, and burner spares.

Included
10 Common Questions

Common Questions on Dock & Feed Wash

01How do automated touchless truck washes prevent pathogen crossover at abattoir docks?
Touchless 20 MPa rotating jets eliminate brushes that trap blood, hair, and ASFV between consecutive vehicles, while strict one-way exit lanes ensure outbound trucks never cross dirty unloading zones.
02Why do slaughterhouse wash bays need 80–100°C hot water instead of cold water?
Animal fat and coagulated blood proteins solidify under cold water, shielding pathogens from chemical disinfectants. Pressurized 80–100°C hot water from our 120 kW boilers emulsifies grease rapidly for complete cleaning.
03Why is the 120 kW natural gas boiler (P10) preferred at large slaughterhouses?
Where piped natural gas is available, the P10 supplies up to 120 L/min at 0–30 MPa and 100°C with low fuel cost and clean soot-free combustion, delivering enough flow to feed full gantry arches and multiple lances simultaneously.
04How does thermal drying protect bulk feed trucks from moisture contamination?
After washing and disinfection, running bulk feed tankers through a P05 700–800 kW thermal drying chamber removes residual moisture completely in 30–45 minutes so dry feed never clumps or molds during delivery.
05How does the 316L high-pressure medicator switch between alkaline foam and disinfectant?
The P13 injects chemicals downstream of the main pump at ±1% accuracy through 316L stainless steel and PTFE seals, switching automatically via PLC/RS485 between alkaline degreasing foam and terminal virucidal spray.
06Can the P02 exterior gantry accommodate tall bulk feed tankers and multi-tier hog rigs?
Yes. With a 4,450 × 1,600 × 4,900 mm full anti-corrosion frame and <4,200 mm vehicle clearance, the P02 handles both multi-deck livestock trailers and commercial bulk feed tankers smoothly.
07How does the P03 chassis washer hold up in bloody, high-mud abattoir wash trenches?
The P03 combines an IP67 waterproof 0.37 kW geared drive, stainless steel drag chain hose protection, and 15–20 MPa 360° rotating nozzles engineered specifically for submerged splash trenches.
08How are drivers and dock staff prevented from carrying pathogens into clean zones?
BioFortis integrates P23 Automatic Heated Two-Hand Disinfection Stations (2 kW, 9 L/min at 65°C) at personnel transitions between live-haul unloading docks and clean dispatch offices.
09What if our feed mill or rendering plant does not have piped natural gas?
For sites without piped gas, BioFortis supplies the P09 120 kW Diesel High-Pressure Boiler (0–30 MPa, 100°C) or zero-emission P11 120 kW Electromagnetic Boiler.
10What throughput capacity can a BioFortis abattoir or feed mill lane sustain?
Paired with a 60 kW IoT pumping skid and automated 7–15 minute wash passes, a single lane handles continuous multi-shift operation and scales easily to 2–3 parallel lanes for 40+ trucks per day.
Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.