Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Downstream High-Pressure Chemical Injection

High-Pressure Proportional Chemical Injection Medicator (0.5–10 MPa, 316L SS, RS485)

BioFortis P13 High-Pressure Proportional Medicator injects concentrated disinfectants directly downstream of your main plunger pump at 0.5–10 MPa (customizable to 25 MPa)—delivering ±1% ratio accuracy (0.03% repeatability), 316L SS/PTFE corrosion immunity, and RS485 Modbus RTU SCADA telemetry.

0.5–10 MPaCustom to 25 MPa
±1% / 0.03%Ratio & Repeatability
316L + PTFEAcid & Aldehyde Safe
RS485 / 4–20mAModbus RTU Telemetry
High-Pressure Proportional Medicator (0.5–10 MPa, RS485)
System Overview

Why Must High-Pressure Livestock Sanitation Lines Inject Disinfectant Downstream of the Main Pump?

BioFortis P13 High-Pressure Proportional Medicators inject corrosive acids, peroxides, and aldehydes downstream of the main high-pressure pump outlet at 0.5–10 MPa (customizable to 25 MPa), keeping ceramic plungers and pump seals exposed only to clean water. Delivering up to 2,700 mL/min with ±1% dynamic ratio accuracy across 1:50–1:1000 and RS485 Modbus RTU telemetry, P13 prevents both pump corrosion and chemical concentration drift.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
0.5–10 MPaCustom 25 MPa Option
2,700 mL/minMax Chemical Injection
±1% Error0.03% Repeatability
RS485 ModbusLive SCADA Logging
Deployment Tiers

Which P13 High-Pressure Injection Configuration Fits Your Central Washout or Abattoir Line?

Select standard 10 MPa or custom 25 MPa discharge back-pressure ratings matched to your centralized cleaning skid or vehicle wash gantry.

Tier 1 · Standard 10 MPa

0.5–10 MPa Central Barn Disinfection Manifold

Dynamic downstream proportional dosing for pressurized barn foam and disinfectant distribution headers.

  • ±1% ratio accuracy across fluctuating multi-gun flow
  • 316L SS, PTFE seals & chemical-grade PE wetted path
  • 1:50–1:1000 digital ratio entry with zero pump contact
Quote 10 MPa P13
Tier 3 · Dual-Chemical SCADA

Twin P13 Skid with RS485 Modbus RTU Telemetry

Dedicated foaming detergent + disinfectant injectors logging real-time consumption directly into group SCADA.

  • Prevents cross-mixing incompatible foam & acid chemicals
  • RS485, Modbus RTU & 4–20 mA I/O audit compliance
  • Zero paper logbooks for multi-site biosecurity audits
Request SCADA P&ID
How It Works

How Does BioFortis P13 Eliminate Pump Corrosion and Maintain ±1% Accuracy Across Dynamic Gun Loads?

Downstream High-Pressure Injection Eliminates Main Pump Corrosion

Downstream High-Pressure Injection Eliminates Main Pump Corrosion

Drawing acids, peroxides, or glutaraldehyde through the inlet of a 60 kW plunger pump destroys valves and ceramic seals within weeks. P13 injects concentrate strictly downstream of the pump discharge so your main pump only ever sees clean water.

316L + PTFECorrosion Proof
0% ContactMain Pump Safe
Dynamic ±1% Ratio Tracking Across Opening & Closing Wash Guns

Dynamic ±1% Ratio Tracking Across Opening & Closing Wash Guns

As barn operators open or close wash lances on a central header, manifold flow swings sharply. P13 tracks live flow dynamically up to 2,700 mL/min chemical output, holding ±1% ratio accuracy and 0.03% repeatability from 1:50 to 1:1000.

±1% Accuracy0.03% Repeat
1:50–1:1000Digital Ratio
RS485 Modbus RTU & 4–20 mA Telemetry for Biosecurity Audits

RS485 Modbus RTU & 4–20 mA Telemetry for Biosecurity Audits

Large swine integrators and abattoirs need verifiable proof that every wash cycle used target chemical concentration. P13 exports live flow, ratio, and consumption telemetry directly to plant PLC or central SCADA dashboards.

Modbus RTURS485 + 4–20mA
2 kWAC 380V Drive
System Layout

Inside the BioFortis P13 High-Pressure Medicator: Four Corrosion-Proof Sub-Assemblies

316L SS & PTFE Wetted Head

Withstands aggressive acids, peroxides, and aldehydes up to 10 MPa (custom 25 MPa).

2 kW AC 380V Precision Drive

Industrial 3-phase drive delivers pulsation-controlled injection up to 2,700 mL/min.

High-Pressure Proportional Medicator (0.5–10 MPa, RS485) structural breakdown
Dynamic 1:50–1:1000 Controller

Tracks real-time header flow to lock ±1% accuracy as wash guns cycle on and off.

RS485 Modbus & 4–20 mA I/O

Native industrial telemetry for remote ratio control and automated compliance logs.

Integrating High-Pressure Downstream Dosing into Your Central Wash Skid or SCADA? Request our 316L injection tee P&ID, Modbus register map, and 10 MPa / 25 MPa FOB/CIF quote within 12 hours.
Technical Specifications

Complete Technical Specifications: P13 High-Pressure Proportional Medicator

Verified factory specifications for the BioFortis P13 industrial high-pressure chemical injector.

ParameterSpecificationNote
Rated VoltageAC 380V / 50Hz3-phase industrial supply (60Hz configurable on export order)
Max Electric Power2 kWHeavy-duty continuous-shift motor drive
Working Pressure Range0.5–10 MPa (Customizable to 25 MPa)Injects directly into pressurized downstream wash manifolds
Dosing Flow Rate2,700 mL/minSupports high-flow truck wash gantries and multi-gun barns
Ratio Adjustment Range1:50 – 1:1000Digital proportional setting across foam & virucide dilutions
Control Accuracy±1% ratio error (0.03% repeatability)Dynamic closed-loop response across fluctuating line flow
CommunicationsRS485, Modbus RTU, 4–20 mA I/ODirect integration with farm PLC and central SCADA
Wetted Materials316L SS, PTFE seals, PEEngineered for strong acid, peroxide & aldehyde disinfectants
Sizing & Site Prep

Engineer Your High-Pressure Dosing Loop: Ratio Calculator, Manifold Spec & Modbus I/O

Interactive Dosing Tool

Disinfectant & Medicator Proportioning Calculator

Calculate exact chemical concentrate consumption and select the right BioFortis proportional medicator for your barn pipeline.

Concentrate Injection Rate--
Daily Chemical Requirement--
Recommended Medicator--
“Keeping a $20,000+ central high-pressure pump running on clean water for life—while delegating harsh acids and aldehydes to a 316L/PTFE downstream injector—is the non-negotiable engineering rule of reliable biosecurity stations.”
BioFortis Chemical Proportioning Engineering
Common Field Problems

Four High-Pressure Chemical Injection Failures BioFortis P13 Eliminates

Field Problem

Upstream Suction Destroying Main Plunger Pumps

How BioFortis Solves It

Downstream injection keeps corrosive chemicals 100% outside ceramic plungers and pump valves.

Field Problem

Concentration Drift When Multiple Guns Open

How BioFortis Solves It

Closed-loop flow tracking maintains ±1% ratio accuracy across dynamic wash-bay demand.

Field Problem

Brass or 304 Fittings Corroding Under Acids

How BioFortis Solves It

Full 316L stainless steel, PTFE seals, and PE wetted path resist harsh oxidizing disinfectants.

Field Problem

Missing Audit Logs for Biosecurity Compliance

How BioFortis Solves It

Native RS485 Modbus RTU and 4–20 mA telemetry record exact chemical usage automatically.

Delivery Process

How BioFortis Configures, Tests & Ships Your P13 High-Pressure Medicator

01

Pressure & Chemistry Check

Confirm 10 MPa vs. custom 25 MPa rating and disinfectant chemical list.

Day 1–2
02

P&ID & Modbus Map

Deliver 316L injection tee schematic and RS485 register documentation.

Day 3–5
03

Full-Backpressure FAT

Calibrate ±1% accuracy and 0.03% repeatability at full operating pressure.

Week 2–3
04

Export Crating

Pack medicator, 316L check valve, and PTFE seal spare kit for shipment.

FOB / CIF
05

SCADA & Commissioning

Support remote Modbus RTU integration and operator calibration training.

24h SLA
Field Validation: Centralized High-Pressure Chemical Dosing Rooms in Vietnam
Field Track Record

Field Validation: Centralized High-Pressure Chemical Dosing Rooms in Vietnam

Installed across 3 commercial swine facilities for a Leading Integrated Commercial Swine Producer in Vietnam, BioFortis centralized dosing rooms standardize automated disinfectant proportioning alongside 20 MPa high-pressure pumping skids.

Testing & Export Docs

What Engineering Documentation Ships with Every P13 High-Pressure Medicator?

DOC-01

Full-Pressure ±1% FAT Certificate

Factory calibration log verifying ratio error and 0.03% repeatability.

Included
DOC-02

316L P&ID & Modbus RTU Manual

Downstream injection manifold drawing plus RS485/4–20 mA point table.

Included
DOC-03

English Operating & Flush SOP

Digital ratio programming, chemistry flush, and seal replacement steps.

Included
DOC-04

Export Docs & 12-Month PTFE BOM

Customs pack plus PTFE seal kit, 316L check valve, and suction strainer.

Included
10 Common Questions

Frequently Asked Questions About the P13 High-Pressure Proportional Chemical Injection Medicator

01How does downstream high-pressure injection protect main plunger pumps from corrosion?
By injecting concentrated disinfectant after the main high-pressure pump outlet (at 0.5–10 MPa or custom 25 MPa), corrosive acids, peroxides, and glutaraldehyde never touch the pump's ceramic plungers, valves, or water seals—extending pump life dramatically.
02How does P13 hold ±1% accuracy when multiple barn wash guns open and close?
P13 monitors live manifold water flow continuously and modulates its 2 kW precision injection drive in real time, maintaining ±1% ratio error and 0.03% repeatability from 1:50 to 1:1000 regardless of how many operators squeeze triggers.
03Can BioFortis build the P13 for our 20 MPa truck wash center?
Yes. While the standard P13 is rated 0.5–10 MPa, BioFortis supplies a custom 25 MPa high-backpressure configuration specifically engineered to inject directly into 20 MPa vehicle wash gantries and centralized barn headers.
04What corrosive farm disinfectants are safe for the P13 wetted path?
All chemical-contact surfaces use 316L stainless steel, PTFE seals, and chemical-grade PE—providing broad compatibility with strong organic acids, peracetic acid, potassium peroxymonosulfate, glutaraldehyde, and alkaline foaming detergents.
05How does P13 connect to our farm PLC or SCADA system?
P13 includes native RS485 (Modbus RTU) and 4–20 mA analog I/O ports so central control rooms can adjust dosing ratios remotely, trigger chemical switching, and log daily consumption for biosecurity audits.
06When should we choose P13 versus P16 (Venturi End Dosing Cart)?
Choose P13 when you want centralized, ±1% digitally controlled dosing with SCADA audit logs feeding an entire wash bay or central header. Choose P16 zero-power mobile Venturi carts when individual barns need flexible room-by-room chemistry switching without electrical cords.
07How does P13 differ from P14 (Medium-Pressure Medicator) and P15 (Electronic Tank Doser)?
P13 handles high-pressure washout headers (0.5–10 MPa, custom 25 MPa) on AC 380V. P14 handles 0–10 bar drinking-water medication and medium-pressure lines on AC 220V. P15 handles non-pressurized holding tank batch mixing.
08Is 2,700 mL/min chemical flow enough for a 120 L/min truck wash gantry?
Yes. At 120 L/min water flow and a 1:50 (2%) heavy foaming ratio, required chemical injection is 2,400 mL/min—comfortably within P13's 2,700 mL/min capacity.
09What electrical supply is required for export installations?
P13 operates on AC 380V / 50Hz three-phase power at 2 kW max load, with 60Hz configurations supplied on export orders.
10What spare parts should we stock for 12 months of continuous operation?
We recommend stocking one 12-month PTFE seal kit, one 316L discharge check valve cartridge, and one suction foot-valve strainer alongside the main unit.
Talk to an Engineer

Request a P&ID Spec, Modbus Map & Quote for the P13 High-Pressure Medicator

Tell us your line pressure (10 MPa vs. custom 25 MPa), chemical types, and SCADA protocol to receive a tailored P13 quote.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.