High-Pressure Proportional Chemical Injection Medicator (0.5–10 MPa, 316L SS, RS485)
BioFortis P13 High-Pressure Proportional Medicator injects concentrated disinfectants directly downstream of your main plunger pump at 0.5–10 MPa (customizable to 25 MPa)—delivering ±1% ratio accuracy (0.03% repeatability), 316L SS/PTFE corrosion immunity, and RS485 Modbus RTU SCADA telemetry.

Why Must High-Pressure Livestock Sanitation Lines Inject Disinfectant Downstream of the Main Pump?
BioFortis P13 High-Pressure Proportional Medicators inject corrosive acids, peroxides, and aldehydes downstream of the main high-pressure pump outlet at 0.5–10 MPa (customizable to 25 MPa), keeping ceramic plungers and pump seals exposed only to clean water. Delivering up to 2,700 mL/min with ±1% dynamic ratio accuracy across 1:50–1:1000 and RS485 Modbus RTU telemetry, P13 prevents both pump corrosion and chemical concentration drift.
Which P13 High-Pressure Injection Configuration Fits Your Central Washout or Abattoir Line?
Select standard 10 MPa or custom 25 MPa discharge back-pressure ratings matched to your centralized cleaning skid or vehicle wash gantry.
0.5–10 MPa Central Barn Disinfection Manifold
Dynamic downstream proportional dosing for pressurized barn foam and disinfectant distribution headers.
- ±1% ratio accuracy across fluctuating multi-gun flow
- 316L SS, PTFE seals & chemical-grade PE wetted path
- 1:50–1:1000 digital ratio entry with zero pump contact
Custom 25 MPa Truck Wash & 20 MPa Central Skid
High-backpressure 25 MPa build engineered for direct downstream injection on 20 MPa truck gantries and P07 skids.
- Protects 60 kW ceramic plunger pumps from harsh acids
- 2,700 mL/min output handles 120 L/min gantry peak flow
- Seamless switching between alkaline foam & virucide
Twin P13 Skid with RS485 Modbus RTU Telemetry
Dedicated foaming detergent + disinfectant injectors logging real-time consumption directly into group SCADA.
- Prevents cross-mixing incompatible foam & acid chemicals
- RS485, Modbus RTU & 4–20 mA I/O audit compliance
- Zero paper logbooks for multi-site biosecurity audits
How Does BioFortis P13 Eliminate Pump Corrosion and Maintain ±1% Accuracy Across Dynamic Gun Loads?
Downstream High-Pressure Injection Eliminates Main Pump Corrosion
Drawing acids, peroxides, or glutaraldehyde through the inlet of a 60 kW plunger pump destroys valves and ceramic seals within weeks. P13 injects concentrate strictly downstream of the pump discharge so your main pump only ever sees clean water.
Dynamic ±1% Ratio Tracking Across Opening & Closing Wash Guns
As barn operators open or close wash lances on a central header, manifold flow swings sharply. P13 tracks live flow dynamically up to 2,700 mL/min chemical output, holding ±1% ratio accuracy and 0.03% repeatability from 1:50 to 1:1000.
RS485 Modbus RTU & 4–20 mA Telemetry for Biosecurity Audits
Large swine integrators and abattoirs need verifiable proof that every wash cycle used target chemical concentration. P13 exports live flow, ratio, and consumption telemetry directly to plant PLC or central SCADA dashboards.
Inside the BioFortis P13 High-Pressure Medicator: Four Corrosion-Proof Sub-Assemblies
Withstands aggressive acids, peroxides, and aldehydes up to 10 MPa (custom 25 MPa).
Industrial 3-phase drive delivers pulsation-controlled injection up to 2,700 mL/min.
Tracks real-time header flow to lock ±1% accuracy as wash guns cycle on and off.
Native industrial telemetry for remote ratio control and automated compliance logs.
Complete Technical Specifications: P13 High-Pressure Proportional Medicator
Verified factory specifications for the BioFortis P13 industrial high-pressure chemical injector.
| Parameter | Specification | Note |
|---|---|---|
| Rated Voltage | AC 380V / 50Hz | 3-phase industrial supply (60Hz configurable on export order) |
| Max Electric Power | 2 kW | Heavy-duty continuous-shift motor drive |
| Working Pressure Range | 0.5–10 MPa (Customizable to 25 MPa) | Injects directly into pressurized downstream wash manifolds |
| Dosing Flow Rate | 2,700 mL/min | Supports high-flow truck wash gantries and multi-gun barns |
| Ratio Adjustment Range | 1:50 – 1:1000 | Digital proportional setting across foam & virucide dilutions |
| Control Accuracy | ±1% ratio error (0.03% repeatability) | Dynamic closed-loop response across fluctuating line flow |
| Communications | RS485, Modbus RTU, 4–20 mA I/O | Direct integration with farm PLC and central SCADA |
| Wetted Materials | 316L SS, PTFE seals, PE | Engineered for strong acid, peroxide & aldehyde disinfectants |
Engineer Your High-Pressure Dosing Loop: Ratio Calculator, Manifold Spec & Modbus I/O
Civil, Electrical & Piping Interface Checklist
- Install a 316L stainless check-valve injection tee downstream of the main high-pressure pump and boiler.
- Include an overpressure relief valve and pulsation dampener rated above 10 MPa (or 25 MPa on custom builds).
- Provide shielded twisted-pair cabling for RS485 Modbus RTU or 4–20 mA SCADA telemetry hookups.
Full AutoCAD (.DWG) and PDF foundation layouts are delivered within 5 business days of order confirmation.
Preventive Maintenance & Wear-Part Intervals
- Flush the 316L pump head with clean water for 2 minutes whenever changing chemical formulations.
- Inspect PTFE seals, suction foot-valve strainer, and 316L injection check valve every 500 operating hours.
- Verify ratio calibration against a graduated cylinder quarterly to confirm ±1% accuracy.
Need consolidated 12-month wear-part kits? See our Genuine Spare Parts Program
Four High-Pressure Chemical Injection Failures BioFortis P13 Eliminates
Upstream Suction Destroying Main Plunger Pumps
Downstream injection keeps corrosive chemicals 100% outside ceramic plungers and pump valves.
Concentration Drift When Multiple Guns Open
Closed-loop flow tracking maintains ±1% ratio accuracy across dynamic wash-bay demand.
Brass or 304 Fittings Corroding Under Acids
Full 316L stainless steel, PTFE seals, and PE wetted path resist harsh oxidizing disinfectants.
Missing Audit Logs for Biosecurity Compliance
Native RS485 Modbus RTU and 4–20 mA telemetry record exact chemical usage automatically.
How BioFortis Configures, Tests & Ships Your P13 High-Pressure Medicator
Pressure & Chemistry Check
Confirm 10 MPa vs. custom 25 MPa rating and disinfectant chemical list.
P&ID & Modbus Map
Deliver 316L injection tee schematic and RS485 register documentation.
Full-Backpressure FAT
Calibrate ±1% accuracy and 0.03% repeatability at full operating pressure.
Export Crating
Pack medicator, 316L check valve, and PTFE seal spare kit for shipment.
SCADA & Commissioning
Support remote Modbus RTU integration and operator calibration training.
Field Validation: Centralized High-Pressure Chemical Dosing Rooms in Vietnam
Installed across 3 commercial swine facilities for a Leading Integrated Commercial Swine Producer in Vietnam, BioFortis centralized dosing rooms standardize automated disinfectant proportioning alongside 20 MPa high-pressure pumping skids.
What Engineering Documentation Ships with Every P13 High-Pressure Medicator?
Full-Pressure ±1% FAT Certificate
Factory calibration log verifying ratio error and 0.03% repeatability.
316L P&ID & Modbus RTU Manual
Downstream injection manifold drawing plus RS485/4–20 mA point table.
English Operating & Flush SOP
Digital ratio programming, chemistry flush, and seal replacement steps.
Export Docs & 12-Month PTFE BOM
Customs pack plus PTFE seal kit, 316L check valve, and suction strainer.
Frequently Asked Questions About the P13 High-Pressure Proportional Chemical Injection Medicator
01How does downstream high-pressure injection protect main plunger pumps from corrosion?
02How does P13 hold ±1% accuracy when multiple barn wash guns open and close?
03Can BioFortis build the P13 for our 20 MPa truck wash center?
04What corrosive farm disinfectants are safe for the P13 wetted path?
05How does P13 connect to our farm PLC or SCADA system?
06When should we choose P13 versus P16 (Venturi End Dosing Cart)?
07How does P13 differ from P14 (Medium-Pressure Medicator) and P15 (Electronic Tank Doser)?
08Is 2,700 mL/min chemical flow enough for a 120 L/min truck wash gantry?
09What electrical supply is required for export installations?
10What spare parts should we stock for 12 months of continuous operation?
Request a P&ID Spec, Modbus Map & Quote for the P13 High-Pressure Medicator
Tell us your line pressure (10 MPa vs. custom 25 MPa), chemical types, and SCADA protocol to receive a tailored P13 quote.
Related Equipment
Request a Quote & CAD Layout
Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.