UPN0102 Compact Automated Veterinary PCR (17 kg)
Random-access benchtop analyzer with independent detection modules for urgent post-drying truck swabs and gilt quarantine.
17 kg · 900 VA · ≤0.5°C · 13.3" Bilingual UI
View UPN0102 Specs
Skip 3-room HVAC builds and dry-ice couriers. Put UPN0102/UPN0104 closed-cartridge screening inside a 15 m² room for <45-minute truck-swab answers.
A BioFortis pig farm PCR testing lab fits inside a standard <15 m² room using 17 kg UPN0102 and 31.5 kg UPN0104 closed-cartridge analyzers. Sealed magnetic-bead extraction and amplification prevent aerosol false positives and eliminate three-room negative-pressure construction.
Pair benchtop closed-cartridge analyzers with room-temperature ASFV, PRRS, and PEDV multiplex kits.
Random-access benchtop analyzer with independent detection modules for urgent post-drying truck swabs and gilt quarantine.
17 kg · 900 VA · ≤0.5°C · 13.3" Bilingual UI
View UPN0102 Specs
High-capacity benchtop system running up to 32 samples per run (8-strip) or 24-pathogen multiplex panels for central hubs.
31.5 kg · 1,800 VA · 32 Samples / 24-Plex
View UPN0104 Specs
Standard ASFV, p72/CD2v/MGF360 triplex, and Genotype I/II differential assays with room-temperature vitrified stability.
Ambient Ship · Built-In IC · Swabs/Blood
View ASFV Kits
Pre-filled 8-strip panels differentiating PEDV/TGEV/PDCoV/PoRV, PRRS NA/EU/HP, PCV2/3, SIV, and GPS/APP/S. suis.
Closed 8-Strip · Under 1 Hr · Ambient Stable
View Multiplex Kits
Opening amplified qPCR tubes inside a small gate room ruins future tests with false positives. BioFortis runs lysis, magnetic-bead purification, and PCR inside one permanently closed tube.
Liquid PCR reagents spoil quickly when couriers get held up reaching rural pig farms. Vitrified cartridges ship at room temperature by regular air courier and carry built-in internal controls.
Use the 17 kg UPN0102 for random-access urgent truck swabs on arrival, or install the 31.5 kg UPN0104 when group screening hubs run up to 32 samples or 24-plex assays.
Simple wipeable bench for environmental truck swabs, oral fluids, blood, and single-step lysis.
900 VA or 1,800 VA automated closed-cartridge analyzer protected by a compact pure-sine UPS.
Room-temperature storage for ASFV, PRRS, PEDV, and FMDV cartridges with zero -20°C freezer storage needed.
USB thermal printer for audit slips plus sealed biohazard disposal for unopened post-run tubes.
Compare our two verified room configurations built directly from BioFortis UPN0102 and UPN0104 factory specifications.
| Parameter | Specification | Note |
|---|---|---|
| Single-Site Gatehouse (UPN0102) | 370×350×340 mm · 17 kg · 900 VA | 10–12 m² room; random-access urgent truck swabs & gilt entry |
| Central Group Hub (UPN0104) | 370×610×340 mm · 31.5 kg · 1,800 VA | 12–15 m² room; up to 32 samples/run (8-strip) or 24-plex |
| Thermal & Optical Precision | 40–95°C · ≤0.5°C accuracy · CV ≤3% | ≥6°C/s heating, ≥4°C/s cooling, ≤15 s full-channel optical scan |
| ASFV Assay Options | Standard / p72-CD2v-MGF360 / Genotype I-II | Differentiates wild-type virulent vs. gene-deleted ASFV variants |
| Swine Multiplex Panels | PRRS NA/EU/HP, PEDV/TGEV/PDCoV/PoRV, FMDV/SVA | Includes PRV gE-deleted, CSFV, PCV2/3, SIV & bacterial triplex |
| User Interface & Export | 13.3-inch English/Chinese touchscreen + USB printer | QR-code cartridge entry with automated curve report slips |
Full AutoCAD (.DWG) and PDF foundation layouts are delivered within 5 business days of order confirmation.
Need consolidated 12-month wear-part kits? See our Genuine Spare Parts Program
Spending $50k+ on 3-Room HVAC Labs Without Staff
Closed-cartridge POCT runs in a standard <15 m² room with existing farm biosecurity personnel.
Open-Tube Aerosol Carryover False Positives
Permanently sealed extraction-and-amplification tubes stop amplicon contamination at the source.
Dry-Ice Cold-Chain Failures at Remote Customs
Vitrified room-temperature cartridges ship via standard air freight with zero thermal spoilage.
Rapid Antigen Strips Missing Low-Load Truck Swabs
Fluorescent PCR (CV ≤3%) catches trace viral DNA on washed trailers that lateral-flow strips miss.
Confirm weekly truck swabs, herd samples, and target swine pathogen panels.
Specify UPN0102 or UPN0104, ambient reagent kits, UPS & prep accessories.
Calibrate ≤0.5°C thermal accuracy and CV ≤3% optics before packing.
Ship flight-cased analyzer and room-temp reagent kits with zero dry ice.
Train gate staff via English video walkthrough and run validation swabs.
Swine integrators place UPN0102 and UPN0104 rooms directly at the clean exit of BioFortis 20 MPa wash and 700–800 kW drying hubs to clear ASFV trailer swabs before gate release.
Bench zoning, power protection, and clean-to-waste workflow blueprint.
Factory verification sheet confirming ≤0.5°C accuracy and CV ≤3%.
Illustrated truck-swabbing, oral-fluid prep, and curve-interpretation manual.
Non-hazardous ambient air-freight docs plus quarterly reagent forecast.
Tell us your weekly trucks, herd size, and target pathogens to receive a complete lab equipment list.