Full-Site Centralized High-Pressure Cleaning System (≤20 MPa)
Centralized multi-pump station and stainless steel piping network delivering up to 20 MPa, 350 L/min, and 100°C hot water to quick-connect d...
Rated Voltage: AC 380V / 50Hz
View SpecsDragging portable washers and 380V cables through wet farrowing and nursery barns creates electrocution hazards, slows turnaround, and spreads PEDV/PRRS between rooms. A BioFortis central high-pressure cleaning system and farm disinfection system pipes 20 MPa hot water (up to 100°C) and calibrated disinfectant through fixed stainless manifolds to every barn drop.

Designed for pig farm high-pressure cleaning, this centralized barn cleaning system and low-pressure disinfection architecture isolates all 380V pumping equipment inside a dry plant room, cutting pig barn washout labor by 35–50% and reducing farm sewage discharge by up to 40% while eliminating cross-barn portable machine transfer.
Deploy our Full-Site High-Pressure Cleaning System for mechanical manure removal and our Full-Site Low-Pressure Disinfection System for automated time-slotted misting.
Centralized multi-pump station and stainless steel piping network delivering up to 20 MPa, 350 L/min, and 100°C hot water to quick-connect d...
Rated Voltage: AC 380V / 50Hz
View Specs
Automated constant-pressure disinfectant distribution station with dual pressure modes (≤5 bar / ≤18 bar), one-duty/one-standby pump redunda...
Rated Voltage: AC 380V / 50Hz
View Specs
Barn staff never drag heavy machines or energized 380V cords into wet farrowing crates. Operators simply snap a lightweight stainless lance into the room's quick-connect drop, open the valve, and wash immediately—cutting empty-barn turnaround labor by 35–50% while removing electrocution risk.
Farm well water often contains high mineral hardness and suspended silt that score ceramic plungers and plug nozzles. BioFortis integrates water softening, bag filtration, and PP cotton filtration upstream of the buffer tank and VFD pump skid to maximize multi-year reliability.
Our centralized low-pressure disinfection station pairs one-duty/one-standby pump redundancy with programmable time-slotted zone cycling (≤5 bar up to 20 T/h or ≤18 bar up to 12 T/h), while downstream proportional dosing keeps corrosive chemicals out of main high-pressure pump heads.
Softener, bag filter, and PP cotton pre-treatment protect ceramic seals, nozzles, and 100°C boiler coils from scale.
7.5–60 kW ceramic plunger pump groups automatically stage on and off to hold constant 20 MPa whether 1 or 12 guns run.
Fixed corrosion-resistant stainless manifolds deliver cold water, hot water, foam, and disinfectant to every room.
Injects calibrated 1:50–1:500 disinfectant after the pump outlet or via mobile Venturi carts for zero pump corrosion.
Verified factory specifications covering both centralized in-farm systems (P07 High-Pressure Cleaning and P08 Low-Pressure Disinfection).
| Parameter | Specification | Note |
|---|---|---|
| High-Pressure System (P07) | ≤20 MPa | ≤350 L/min | 7.5–60 kW | AC 380V/50Hz; VFD multi-pump constant pressure |
| Hot Water Capability (P07) | Up to 100°C Outlet | Pairs directly with 120 kW central boilers (C04) |
| Low-Pressure Mode (P08) | ≤5 bar (≤20 T/h) | 22 kW | Overhead misting & corridor saturation |
| High-Pressure Disinfection Mode (P08) | ≤18 bar (≤12 T/h) | 22 kW | Manual spray-wand barn & loading-chute disinfection |
| Dosing & Pre-Treatment | 1:50–1:500 | Softener + Bag + PP | Protects pumps and maintains verified viral kill ratios |
| Redundancy & Piping | Duty-Standby Pumps | 304/316L SS | Time-slotted zone cycling with low-level & overpressure alarms |
Full AutoCAD (.DWG) and PDF foundation layouts are delivered within 5 business days of order confirmation.
Need consolidated 12-month wear-part kits? See our Genuine Spare Parts Program
Electrocution Hazards from Wet-Floor Cables
100% water-and-electricity separation keeps all 380V motors, VFDs, and control panels locked inside a dry utility room.
Cross-Barn PEDV/PRRS Transfer via Portable Washers
Fixed stainless piping eliminates wheeling contaminated portable machines from nursery to farrowing rooms.
Pressure Drops When Multiple Operators Wash Together
VFD multi-pump staging automatically scales output up to 350 L/min so line pressure stays locked at 20 MPa.
Excessive Farm Sewage & Lagoon Treatment Costs
High-impact 20 MPa hot-water scouring cuts barn wash water volume and sewage discharge by up to 40%.
Review sow capacity, building spacing, peak simultaneous guns, and raw water quality.
Deliver stainless header sizing, quick-connect drop maps, and dry plant room utility layouts.
Pressure-test VFD pump skids, pulsation stability, and safety interlocks at full 20 MPa before dispatch.
Ship pre-assembled pump skids, filtration units, stainless fittings, and 12-month spare kits.
Guide site piping pressure tests, VFD tuning, and bilingual operator SOP handover.
A Leading Integrated Commercial Swine Producer in Vietnam standardized on BioFortis centralized high-pressure pump skids, stainless buffer tanks, and automated proportioning rooms across 3 commercial sites—eliminating portable washer downtime and delivering consistent 20 MPa barn turnaround performance.
Factory test logs confirming VFD multi-pump staging, pressure stability, and safety shutoffs.
DWG/PDF plant room layout, 304/316L manifold sizing, and room-by-room quick-connect drop locations.
Manuals covering VFD operation, softener regeneration, filter changes, and dosing calibration.
Export invoices, HS codes, and itemized wear-part kits (filter cartridges, seals, lances, couplers).
Share your barn layout and concurrent gun count for stainless piping CAD drawings and pump skid quotes—or explore our 120 kW boilers and precision medicators.
Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.