Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Automated Chemical & Drug Proportioning

Precision Dosing Pumps & Livestock Water Medicators (1:50–1:1000)

Under-dosed disinfectants fail to inactivate African Swine Fever Virus; over-dosed chemicals corrode barn steel and waste thousands of dollars annually. BioFortis precision medicators cover every farm pressure zone from non-pressurized tanks and 0–10 bar drinking lines up to 10–25 MPa high-pressure manifolds at ±1% to 99.6% accuracy.

99.6% / ±1%Verified Dosing Accuracy
1:50–1:1000Digital Ratio Range
0–10 MPa+Full Pressure Coverage
RS485 ModbusSCADA Telemetry Ready
Precision Dosing & Water Medicators
System Overview

Why Do Commercial Swine Farms Replace Mechanical Piston Injectors with Digital Precision Water Medicators?

BioFortis precision swine water medicators and high-pressure chemical injection pumps hold ±1% to 99.6% proportioning accuracy across dynamic barn water flows from 1:50 to 1:1000, eliminating pressure-induced drift, manual bucket mixing errors, and premature plunger-pump corrosion.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
99.6%Medium-Pressure Accuracy
±1% (0.03%)High-Pressure Error & Repeat
1:50–1:1000Programmable Ratio Span
316L + PTFEAcid & Oxidizer Rated
Series Lineup (4 Models)

Which BioFortis Dosing System Fits Your Pressure Zone and Chemical Protocol?

Match your exact hydraulic zone across our four specialized architectures: High-Pressure RS485, Medium-Pressure Touchscreen, Non-Pressurized Tank Batch, and Zero-Power Venturi Cart.

P13 High-Pressure Proportional Medicator (0.5–10 MPa, RS485)

High-Pressure Proportional Medicator (0.5–10 MPa, RS485)

Dynamic high-pressure proportional disinfectant injector operating at 0.5–10 MPa (customizable to 25 MPa) with ±1% ratio accuracy, 316L stai...

Rated Voltage: AC 380V / 50Hz

View Specs
P14 Medium-Pressure Touchscreen Water Medicator (0–10 bar)

Medium-Pressure Touchscreen Water Medicator (0–10 bar)

Digital touchscreen proportional water medicator delivering 99.6% dosing accuracy across 0–10 bar pressurized pipelines for swine drinking-w...

Rated Voltage: AC 220V / 50Hz

View Specs
P15 Electronic Standard Non-Pressurized Disinfectant Dosing System

Electronic Standard Non-Pressurized Disinfectant Dosing System

Touchscreen electronic proportioning unit (2–100 L/min water flow, 0–1.905 L/min chemical capacity) for automated batch preparation of exact...

Rated Voltage: AC 220V / 50Hz

View Specs
P16 High-Pressure Venturi End Dosing Cart (304 Stainless Steel)

High-Pressure Venturi End Dosing Cart (304 Stainless Steel)

Zero-electricity 304 stainless steel mobile Venturi dosing cart rated 15–20 MPa with integrated hose reel, universal casters, and instant ri...

Frame Material: 304 Stainless Steel

View Specs
How It Works

How Does BioFortis Guarantee ±1% Dosing Accuracy Under Dynamic Farm Flows?

Downstream High-Pressure Injection Keeps Corrosive Disinfectants Out of Main Pumps

Downstream High-Pressure Injection Keeps Corrosive Disinfectants Out of Main Pumps

Drawing acids, peroxides, or glutaraldehyde through a high-pressure ceramic plunger pump destroys valves and water seals rapidly. Our P13 High-Pressure Medicator injects concentrate downstream at 0.5–10 MPa (customizable to 25 MPa) through 316L stainless steel and PTFE seals, protecting your main pumping station.

0.5–10 MPaCustom up to 25 MPa
316L SSPTFE & PE Wetted Path
Touchscreen Ratio Entry & Pressure-Independent Electronic Accuracy (99.6%)

Touchscreen Ratio Entry & Pressure-Independent Electronic Accuracy (99.6%)

Mechanical water-driven piston medicators lose accuracy when barn pressure fluctuates and require manual sleeve changes for different ratios. BioFortis P14 and P15 electronic units let staff dial any ratio from 1:50 to 1:1000 directly on a digital touchscreen with up to 99.6% accuracy.

99.6%Pressure-Independent
1:50–1:1000Instant Ratio Change
Zero-Electricity 304 SS Venturi End Cart for Wet Barn Quick-Connect Drops

Zero-Electricity 304 SS Venturi End Cart for Wet Barn Quick-Connect Drops

Where electrical cords cannot enter wet farrowing or nursery rooms, the P16 304 stainless steel Venturi cart plugs straight into any 15–20 MPa central drop. A quarter-turn valve switches instantly between high-pressure clean water rinsing and foam/disinfectant application with an integrated hose reel.

0 WattsPure Hydraulic Suction
15–20 MPaQuarter-Turn Switch
System Layout

Inside a 316L Stainless Precision Medicator: Four Corrosion-Proof Sub-Assemblies

316L SS & PTFE Dosing Head

Chemical-grade wetted components resist oxidizing peroxides, organic acids, and aldehyde disinfectants continuously.

Dynamic Flow Tracking Loop

Pulse flow-meter feedback adjusts injection strokes automatically as barn guns or drinkers open and close.

Precision Dosing & Water Medicators structural breakdown
Industrial Touchscreen HMI

Direct digital entry from 1:50 to 1:1000 eliminates manual sleeve adjustments and stock-solution math errors.

RS485 / Modbus RTU Telemetry

Streams real-time chemical consumption and alarm status to central farm SCADA for auditable biosecurity compliance.

Need Chemical Compatibility Verification & Dosing Room Schematics? Tell us your pipeline pressure, flow range, and active chemicals to receive model sizing, Modbus register maps, and FOB/CIF quotes within 12 hours.
Technical Specifications

What Are the Exact Technical Specifications Across All Four BioFortis Medicators?

Complete engineering comparison covering P13 High-Pressure, P14 Medium-Pressure, P15 Non-Pressurized Electronic, and P16 Venturi End Dosing Cart.

ParameterSpecificationNote
P13 High-Pressure Medicator0.5–10 MPa (Custom 25 MPa) | 2,700 mL/min±1% (0.03% repeat); 316L/PTFE; RS485/Modbus/4–20 mA; AC 380V 2 kW
P14 Medium-Pressure Medicator0–10 bar | 3 L/min | Up to 99.6%1:50–1:1000 touchscreen; pulse meter & SCADA port; AC 220V
P15 Electronic Non-Pressurized2–100 L/min Water | 0–1.905 L/min Dose1:50–1:1000 touchscreen; tank batch mixing; quick-change tubing; AC 220V
P16 Venturi End Dosing Cart15–20 MPa | ≥15 L/min | Zero Power304 SS frame, integrated hose reel, casters, rinse/disinfect valve
Ratio Adjustment Span1:50 to 1:1000 (Digital Models)Covers virucidal disinfectants, organic acids & therapeutics
Wetted Path Protection316L SS, PTFE Seals, Chemical PE, 304 SSEngineered for harsh farm sanitation and therapeutic solutions
Sizing & Site Prep

How Do You Calculate Daily Disinfectant Consumption, Ratio Settings, and ROI?

Interactive Dosing Tool

Disinfectant & Medicator Proportioning Calculator

Calculate exact chemical concentrate consumption and select the right BioFortis proportional medicator for your barn pipeline.

Concentrate Injection Rate--
Daily Chemical Requirement--
Recommended Medicator--
“A 20% dilution error can invalidate an entire biosecurity washout. Auditable ±1% to 99.6% digital proportioning protects both your herd immunity and your annual chemical budget.”
BioFortis Fluid Dosing Engineering · Downstream Corrosion-Free Architecture
Common Field Problems

What Dosing & Chemical Injection Failures Does BioFortis Eliminate?

Field Problem

Disinfectants Destroying High-Pressure Pump Heads

How BioFortis Solves It

P13 downstream injection (10–25 MPa) and P16 end-point Venturi carts keep corrosive agents completely clear of ceramic plunger pumps.

Field Problem

Pressure Fluctuations Causing Under-Dosed Treatments

How BioFortis Solves It

P14 electronic closed-loop dosing maintains up to 99.6% accuracy regardless of barn drinking-line pressure swings.

Field Problem

Manual Bucket Mixing Errors & Operator Burns

How BioFortis Solves It

P15 non-pressurized electronic proportioner draws directly from original drums to fill holding tanks accurately at 2–100 L/min.

Field Problem

Plastic Pump Heads Cracking Under Oxidizers

How BioFortis Solves It

316L stainless steel, PTFE seals, and chemical-grade PE wetted parts withstand continuous acid and peroxide exposure.

Delivery Process

How Does BioFortis Configure and Deliver Custom Farm Dosing Systems?

01

Pressure & Chemical Audit

Confirm pipeline pressure, flow range, target dilution ratios, and active disinfectants.

Day 1–2
02

Bypass & Modbus Spec

Provide bypass plumbing diagrams, pulse meter sizing, and RS485 register maps.

Day 3–5
03

Wet-Bench Accuracy FAT

Calibrate every unit on a flow bench to verify ±1% or 99.6% dosing accuracy.

Week 2–3
04

Export Packing & Seals

Ship in corrosion-safe export crates with spare PTFE seals, tubing, and foot valves.

Week 3–4
05

Remote HMI & SCADA Setup

Guide touchscreen programming, ratio locks, and Modbus RTU telemetry integration.

On-Site
Field Validation: Centralized Chemical Dosing & Proportioning Rooms in Vietnam
Field Track Record

Field Validation: Centralized Chemical Dosing & Proportioning Rooms in Vietnam

Across 3 commercial breeding and finishing sites, a Leading Integrated Commercial Swine Producer in Vietnam deployed BioFortis centralized twin-tank dosing rooms to eliminate manual bucket mixing and standardize virucidal dilution across washout lanes and barns.

Testing & Export Docs

What Engineering Documentation Ships with Every BioFortis Medicator?

DOC-01

Wet-Bench Calibration Sheet

Factory flow-bench test records verifying proportioning accuracy across target ratios.

Included
DOC-02

Bypass P&ID & Modbus Manual

Piping installation drawings, pulse meter wiring, and RS485 / 4–20 mA register maps.

Included
DOC-03

English Touchscreen & Flush SOP

Clear operator guide for ratio programming, drum changeovers, and chemical flushing.

Included
DOC-04

Customs & 12-Month Seal BOM

Export invoices, HS codes, and spare PTFE seal, check-valve, and tubing kit list.

Included
10 Common Questions

Frequently Asked Questions About Swine Water Medicators & Precision Dosing Pumps

01Can the medium-pressure medicator handle both drinking-water antibiotics and barn disinfection?
Yes. The P14 operates across 0–10 bar at up to 99.6% accuracy with chemical-resistant wetted parts and a 1:50–1:1000 touchscreen range, handling both swine drinking-water therapeutics/organic acids and pressurized disinfection lines.
02How does downstream high-pressure dosing extend main pump life?
By injecting concentrated disinfectant after the high-pressure pump discharge at 0.5–10 MPa (customizable to 25 MPa), corrosive acids, peroxides, and aldehydes never touch ceramic plungers, valves, or pump water seals.
03Why is a digital touchscreen medicator more accurate than a mechanical water-driven piston pump?
Mechanical water-driven pumps rely on hydraulic differential pressure and wear rapidly under hard water or silt. Digital closed-loop medicators track pulse flow electronically to hold ±1% to 99.6% accuracy even when barn water pressure fluctuates.
04What dosing ratio range do BioFortis electronic medicators support?
P13, P14, and P15 all support programmable ratios from 1:50 to 1:1000, covering concentrated virucidal disinfectants, foaming detergents, organic acidifiers, vaccines, and drinking-water antibiotics without swapping hardware.
05How does the P13 integrate with farm SCADA or PLC audit systems?
The P13 High-Pressure Proportional Medicator includes native RS485, Modbus RTU, and 4–20 mA I/O ports so central biosecurity control rooms can log real-time chemical consumption and receive low-drum alarms.
06When should a farm use the P15 non-pressurized electronic dosing system?
Choose the P15 (2–100 L/min water flow, 0–1.905 L/min chemical output) whenever you need automated, error-free batch preparation for unpressurized disinfectant holding tanks feeding low-pressure misting stations (P08).
07When is the zero-power P16 Venturi end dosing cart the best choice?
Use the 304 stainless steel P16 cart (15–20 MPa, ≥15 L/min) inside wet pig barns where electrical cords are prohibited, plugging straight into centralized quick-connect drops to switch between clean water rinse and foam disinfection.
08What wetted materials resist harsh farm disinfectants like glutaraldehyde and peracetic acid?
BioFortis specifies 316L stainless steel, PTFE seals, and chemical-grade PE on high-pressure models and 304 stainless steel on Venturi carts to ensure long service life under oxidizing and acidic sanitizers.
09Do BioFortis medicators support 60Hz power grids outside Asia and Europe?
Yes. Standard electronic models run on AC 220V/50Hz (P14/P15) or AC 380V/50Hz (P13), and 60Hz export configurations are built to order for Latin American and North American farms.
10What routine maintenance keeps precision medicators running accurately?
Flush the dosing head with clean water when switching chemicals, clean the suction foot-valve strainer monthly, and replace PTFE seals or quick-change tubing annually using our OEM spare kit.
Talk to an Engineer

Ready to Upgrade Your Farm Water Medication & Disinfectant Dosing?

Tell us your operating pressure zone (non-pressurized, 0–10 bar, 0.5–10 MPa, or 15–20 MPa Venturi) for exact model sizing and a 12-hour quote.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.