Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Veterinary PCR Diagnostics · Model P19

African Swine Fever Virus (ASFV) Closed-Cartridge Fluorescent PCR Reagent Kits

BioFortis closed-cartridge African Swine Fever Virus (ASFV) fluorescent PCR reagent kits deliver single-step, aerosol-free molecular detection across three specialized assays—Standard ASFV, p72/CD2v/MGF360 triplex, and Genotype I/II differential—shipped globally at room temperature.

3 ASFV AssaysStandard / Triplex / I-II
Closed CartridgeExtraction + PCR Integrated
Ambient VitrifiedZero Dry-Ice Shipping
Built-In ICEvery-Tube Quality Control
African Swine Fever Virus (ASFV) Fluorescent PCR Reagent Kits
System Overview

Why Do Commercial Swine Integrators Upgrade from Single-Gene & Antigen Tests to Closed-Cartridge ASFV Multiplex PCR?

BioFortis African Swine Fever Virus (ASFV) Fluorescent PCR Reagent Kits provide pre-filled closed extraction-and-amplification cartridges covering standard ASFV screening, p72/CD2v/MGF360 triplex differentiation, and Genotype I/II differential detection with ambient-temperature vitrified reagent stability. Commercial swine producers detect low-viral-load trailer swabs and field gene-deleted variants accurately at the biosecurity gate without cold-chain shipping failures or open-tube contamination.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
3 Assay VariantsStandard, Triplex & Genotype I/II
Room-Temp ShipVitrified Ambient Stabilization
4 Sample TypesSwabs, Oral Fluid, Blood, Tissue
100% Internal QCBlocks False-Negative Releases
Deployment Tiers

Which ASFV PCR Assay Variant Matches Your Surveillance Protocol?

Select the ASFV cartridge configuration calibrated to your regional strain landscape, gate-clearance budget, and differential diagnostic objectives on UPN0102 or UPN0104 analyzers.

Tier 01 · Routine Gate Screening

Standard ASFV Fluorescent PCR Kit

Cost-optimized closed-cartridge assay for daily high-frequency environmental swab checks after truck wash-and-dry cycles.

  • High-sensitivity ASFV target detection on dried trailer swabs
  • One-step lysate addition into pre-filled closed cartridges
  • Built-in internal control (IC) verifies valid extraction per well
Quote Standard ASFV Kit
Tier 03 · Strain Epidemiology

Genotype I / II Differential ASFV Kit

Engineered for commercial swine groups tracking co-circulating Genotype I, Genotype II, and recombinant strains.

  • Distinguishes ASFV Genotype I and Genotype II in one closed run
  • Compatible with whole blood, oral fluids, tissue, and swabs
  • Runs seamlessly on both UPN0102 and 32-sample UPN0104
Request Genotype I/II Quote
System Layout

Inside a BioFortis Closed ASFV PCR Cartridge: Four Integrated Safeguards

01 · Single-Step Sealed Loading Port

Technician transfers swab lysate once and snaps the cap shut—keeping lysis, extraction, and amplicons sealed from start to disposal.

02 · Integrated Magnetic-Bead Purification

Three-stage automated magnetic binding and wash buffers strip manure, disinfectant, and blood PCR inhibitors before amplification.

African Swine Fever Virus (ASFV) Fluorescent PCR Reagent Kits structural breakdown
03 · Vitrified Multiplex Reagent Matrix

Pre-dispensed room-temperature stable probes target p72, CD2v, MGF360, or Genotype I/II sequences with zero manual master-mix pipetting.

04 · Built-In Internal Quality Control (IC)

Co-amplified internal control channel validates nucleic acid recovery and enzymatic reaction integrity on every single truck swab.

How It Works

Three Field Advantages Over Open Lab PCR Kits and Rapid Antigen Strips

01. Differentiates Wild-Type, Gene-Deleted & Genotype I/II Variants

01. Differentiates Wild-Type, Gene-Deleted & Genotype I/II Variants

Field circulation of CD2v/MGF360-deleted and Genotype I/II recombinant ASFV variants renders single-gene assays and antigen lateral-flow strips blind to subclinical shedders. BioFortis multiplex closed cartridges resolve p72, CD2v, MGF360, and Genotype I/II markers simultaneously inside a single sealed reaction.

p72/CD2v/MGF360Wild vs Gene-Deleted
Genotype I / IIDual Strain Typing
02. Ambient Vitrified Chemistry Eliminates Dry-Ice Cold-Chain Failures

02. Ambient Vitrified Chemistry Eliminates Dry-Ice Cold-Chain Failures

Conventional liquid PCR master mixes degrade during tropical customs delays or rural courier legs when dry ice sublimates. BioFortis vitrified stabilization keeps pre-filled ASFV reagent cartridges stable at ambient room temperature, cutting air-freight weight and preventing spoiled batch write-offs.

0 kg Dry IceStandard Air Courier
Pre-Filled 8-StripReady for Immediate Run
03. Verified Across Environmental Truck Swabs, Oral Fluids, Blood & Tissue

03. Verified Across Environmental Truck Swabs, Oral Fluids, Blood & Tissue

Unlike antigen cards restricted to high-titer clinical blood from terminal pigs, BioFortis closed-cartridge fluorescent PCR is engineered for low-burden post-drying environmental trailer swabs, group oral-fluid ropes, EDTA whole blood, and spleen/lymph node tissue homogenates.

4 Sample MatricesSwab / Oral / Blood / Tissue
Closed CartridgeZero Post-PCR Aerosol
Need ASFV Triplex or Genotype I/II Reagent Datasheets & Volume Pricing? Tell us your monthly truck-swab count and preferred ASFV assay variant—our veterinary team responds within 12 business hours with tiered kit pricing and analyzer bundle options.
Technical Specifications

Complete Technical Specifications: BioFortis ASFV Fluorescent PCR Reagent Kits

All three ASFV reagent formulations share identical closed-cartridge operation and ambient shipping stability across UPN0102 and UPN0104 platforms.

ParameterSpecificationNote
Assay Variants1) Standard ASFV PCR; 2) ASFV p72/CD2v/MGF360 Triplex; 3) Genotype I / II Differential ASFVCovers routine gate screening to strain differentiation
Compatible AnalyzersUPN0102 & UPN0104 Automated Fluorescent PCR SystemsQR-code auto-protocol recognition
Reagent FormatPre-filled closed cartridge (extraction + amplification integrated)Single-step loading; zero open-tube post-PCR steps
Transport & StorageVitrified room-temperature transport technologyShips without dry-ice cold-chain logistics
Validated Sample TypesEnvironmental truck swabs, oral fluids, whole blood, tissue homogenatesMatches wash-bay and barn surveillance points
Internal Quality ControlBuilt-in endogenous/exogenous IC channel per reactionFlags extraction failure or swab inhibition automatically
Sizing & Site Prep

Calculate Monthly ASFV Cartridge Consumption & Sampling Workflow

Interactive Diagnostics Tool

On-Farm PCR Screening Throughput & Analyzer Selector

Calculate weekly swab volume and determine whether the UPN0102 compact or UPN0104 high-throughput analyzer matches your farm biosecurity schedule.

Weekly Screening Volume--
Monthly Reagent Kit Demand--
Recommended Platform--
“Against low-burden truck biofilm and gene-deleted ASFV variants, only closed-cartridge multiplex fluorescent PCR with internal QC protects the farm gate.”
BioFortis Veterinary Diagnostics Engineering Desk · ASFV Gate Surveillance Division
Common Field Problems

Four ASFV Testing Failures Solved by BioFortis Closed-Cartridge Kits

Field Problem

Lateral-flow antigen strips miss low-viral-load trailer swabs after washout

How BioFortis Solves It

Fluorescent PCR amplification detects trace residual ASFV nucleic acids inside closed cartridges with built-in magnetic purification.

Field Problem

Single-gene p72 tests cannot distinguish wild-type ASFV from CD2v/MGF360 deletions

How BioFortis Solves It

BioFortis Triplex and Genotype I/II differential cartridges resolve multiple target loci simultaneously inside one reaction.

Field Problem

Frozen liquid reagents spoil during international customs clearance delays

How BioFortis Solves It

Vitrified room-temperature reagent stabilization maintains full analytical performance through ambient air freight without dry ice.

Field Problem

Uncontrolled extraction inhibition creates dangerous false-negative truck releases

How BioFortis Solves It

Every cartridge contains an internal quality control channel verifying valid extraction and amplification before displaying a negative result.

Delivery Process

From Sample Swab to Gate Clearance — Plus Hassle-Free Ambient Export Supply

01

Select Assay Variant

Choose Standard, p72/CD2v/MGF360 Triplex, or Genotype I/II based on surveillance need.

DAY 1
02

Ambient Air Dispatch

Cushioned export cartons ship by air courier worldwide with zero dry ice required.

3–7 DAYS
03

Single-Step Swab Load

Mix swab in lysis buffer, transfer once into pre-filled cartridge, and snap cap closed.

2 MIN
04

Automated Closed PCR

Scan QR code on UPN0102 or UPN0104; extraction and amplification run automatically.

AUTO RUN
05

Gate Ticket & Archive

Verify IC-validated curve and print thermal clearance ticket before trailer dispatch.

VERIFIED
Field Workflow: Post-Drying Livestock Truck Swabs & Quarantine Screening
Field Track Record

Field Workflow: Post-Drying Livestock Truck Swabs & Quarantine Screening

Leading commercial swine hubs link physical 20 MPa washout and 70°C+ thermal drying directly to molecular ASFV release checks. Environmental swabs taken from dried multi-tier hog trailers and incoming gilt blood samples run side by side inside sealed BioFortis cartridges, establishing documented proof of negative status before gate entry.

Testing & Export Docs

What Quality & Export Documentation Ships with Every ASFV Reagent Batch?

DOC-01

Lot Certificate of Analysis (COA)

Batch sensitivity, specificity, and internal-control verification documentation per lot.

Per Batch
DOC-02

English Sampling & Loading SOP

Visual instructions for truck swabs, oral fluids, whole blood, and single-step cartridge loading.

Print + PDF
DOC-03

Multiplex Channel Interpretation Guide

Clear threshold and target readout matrix for p72, CD2v, MGF360, Genotype I/II, and IC.

Included
DOC-04

Non-Hazardous Ambient Air Declaration

Export packing list, commercial invoice, and ambient air-freight compliance paperwork.

Export Ready
10 Common Questions

Frequently Asked Questions About BioFortis ASFV Fluorescent PCR Reagent Kits

01Why is fluorescent PCR far more reliable than antigen rapid strips for ASFV truck swab screening?
Lateral-flow antigen rapid strips require high viral protein loads and frequently yield false negatives on washed livestock trailers or early-stage subclinical pigs. Fluorescent PCR exponentially amplifies trace ASFV nucleic acids following automated magnetic-bead purification inside sealed cartridges, catching low-burden residual contamination reliably.
02What is the difference between Standard ASFV, p72/CD2v/MGF360 Triplex, and Genotype I/II Differential kits?
Standard ASFV targets conserved viral sequence for cost-effective daily gate screening. The p72/CD2v/MGF360 Triplex differentiates wild-type virulent strains from gene-deleted variants, while the Genotype I/II Differential assay separates Asian circulating Genotype I and Genotype II ASFV strains in one cartridge.
03Do BioFortis ASFV PCR reagent kits require dry-ice cold-chain shipping?
No. BioFortis pre-filled ASFV reagent cartridges use vitrified room-temperature stabilization technology, allowing standard ambient air-freight delivery to Southeast Asia, Africa, Europe, and Latin America without dry ice, heavy insulated foam containers, or costly cold-chain customs spoilage during multi-day international transit.
04What sample types work with BioFortis closed-cartridge ASFV PCR kits?
The integrated magnetic-bead extraction chemistry processes composite environmental livestock truck swabs, pen-level oral-fluid cotton rope squeezes, EDTA anticoagulated whole blood, and spleen or lymph-node tissue homogenates—covering both post-drying perimeter trailer verification and internal barn clinical surveillance without external extraction kits.
05How does the built-in internal quality control prevent false-negative field reports?
Every cartridge contains an internal control (IC) co-amplified alongside ASFV target genes. If dirt, residual disinfectant, or incomplete sample mixing inhibits extraction or amplification, the IC curve fails and alerts the operator to retest rather than issuing a false negative.
06Which PCR analyzers are compatible with BioFortis pre-filled ASFV cartridges?
All three ASFV reagent kits are engineered specifically for BioFortis UPN0102 compact analyzers (17 kg, ideal for single-farm gates and mobile vets) and UPN0104 high-throughput analyzers (31.5 kg, screening up to 32 samples per run via 8-strip cartridges) with automatic QR-code protocol recognition.
07How does closed-cartridge format prevent PCR contamination inside a farm room?
Unlike open-plate qPCR workflows that require transferring extracted DNA and opening amplified reaction plates, BioFortis reagents stay physically sealed inside disposable cartridges immediately after single-step lysate loading. Amplified ASFV DNA never escapes prior to sealed biohazard bag disposal inside compact farm offices.
08Can farms combine different ASFV variants with PRRS or PEDV kits in one quarterly order?
Yes. Because every BioFortis swine cartridge shares ambient room-temperature storage and UPN0102/UPN0104 analyzer compatibility, commercial pork producers routinely consolidate Standard ASFV, p72/CD2v/MGF360 Triplex, Genotype I/II Differential, and respiratory or diarrhea multiplex kits into one quarterly air-freight order to save shipping costs.
09How much training does biosecurity gate staff need to run an ASFV PCR check?
Gate technicians require minimal hands-on training because cell lysis, magnetic-bead purification, and fluorescence cycling execute automatically inside each sealed cartridge. Staff simply mix the swab, transfer one measured lysate volume, snap the cap closed, scan the QR code, and tap Start.
10When should a farm test post-drying livestock trailers for ASFV?
Biosecurity protocols recommend collecting composite environmental swabs from cab pedals, wheel wells, tailgate ramps, and slat seams immediately after livestock trailers complete 20 MPa washout, chemical disinfection, and 70°C+ thermal drying—verifying negative ASFV DNA status before granting farm gate clearance.
Talk to an Engineer

Request ASFV PCR Reagent Pricing, Assay Datasheet & Analyzer Bundle

Specify your preferred ASFV assay variants (Standard, Triplex, Genotype I/II) and monthly testing volume to receive factory-direct pricing and analyzer bundle quotes within 12 business hours.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.