African Swine Fever Virus (ASFV) Closed-Cartridge Fluorescent PCR Reagent Kits
BioFortis closed-cartridge African Swine Fever Virus (ASFV) fluorescent PCR reagent kits deliver single-step, aerosol-free molecular detection across three specialized assays—Standard ASFV, p72/CD2v/MGF360 triplex, and Genotype I/II differential—shipped globally at room temperature.

Why Do Commercial Swine Integrators Upgrade from Single-Gene & Antigen Tests to Closed-Cartridge ASFV Multiplex PCR?
BioFortis African Swine Fever Virus (ASFV) Fluorescent PCR Reagent Kits provide pre-filled closed extraction-and-amplification cartridges covering standard ASFV screening, p72/CD2v/MGF360 triplex differentiation, and Genotype I/II differential detection with ambient-temperature vitrified reagent stability. Commercial swine producers detect low-viral-load trailer swabs and field gene-deleted variants accurately at the biosecurity gate without cold-chain shipping failures or open-tube contamination.
Which ASFV PCR Assay Variant Matches Your Surveillance Protocol?
Select the ASFV cartridge configuration calibrated to your regional strain landscape, gate-clearance budget, and differential diagnostic objectives on UPN0102 or UPN0104 analyzers.
Standard ASFV Fluorescent PCR Kit
Cost-optimized closed-cartridge assay for daily high-frequency environmental swab checks after truck wash-and-dry cycles.
- High-sensitivity ASFV target detection on dried trailer swabs
- One-step lysate addition into pre-filled closed cartridges
- Built-in internal control (IC) verifies valid extraction per well
ASFV p72 / CD2v / MGF360 Triplex Kit
Essential for regions circulating gene-deleted ASFV strains where single-target assays cannot distinguish wild-type virulence.
- Simultaneously amplifies p72, CD2v, and MGF360 gene targets
- Differentiates wild-type strains from CD2v/MGF360-deleted variants
- Ambient vitrified stability for 12-month farm reserve stock
Genotype I / II Differential ASFV Kit
Engineered for commercial swine groups tracking co-circulating Genotype I, Genotype II, and recombinant strains.
- Distinguishes ASFV Genotype I and Genotype II in one closed run
- Compatible with whole blood, oral fluids, tissue, and swabs
- Runs seamlessly on both UPN0102 and 32-sample UPN0104
Inside a BioFortis Closed ASFV PCR Cartridge: Four Integrated Safeguards
Technician transfers swab lysate once and snaps the cap shut—keeping lysis, extraction, and amplicons sealed from start to disposal.
Three-stage automated magnetic binding and wash buffers strip manure, disinfectant, and blood PCR inhibitors before amplification.
Pre-dispensed room-temperature stable probes target p72, CD2v, MGF360, or Genotype I/II sequences with zero manual master-mix pipetting.
Co-amplified internal control channel validates nucleic acid recovery and enzymatic reaction integrity on every single truck swab.
Three Field Advantages Over Open Lab PCR Kits and Rapid Antigen Strips
01. Differentiates Wild-Type, Gene-Deleted & Genotype I/II Variants
Field circulation of CD2v/MGF360-deleted and Genotype I/II recombinant ASFV variants renders single-gene assays and antigen lateral-flow strips blind to subclinical shedders. BioFortis multiplex closed cartridges resolve p72, CD2v, MGF360, and Genotype I/II markers simultaneously inside a single sealed reaction.
02. Ambient Vitrified Chemistry Eliminates Dry-Ice Cold-Chain Failures
Conventional liquid PCR master mixes degrade during tropical customs delays or rural courier legs when dry ice sublimates. BioFortis vitrified stabilization keeps pre-filled ASFV reagent cartridges stable at ambient room temperature, cutting air-freight weight and preventing spoiled batch write-offs.
03. Verified Across Environmental Truck Swabs, Oral Fluids, Blood & Tissue
Unlike antigen cards restricted to high-titer clinical blood from terminal pigs, BioFortis closed-cartridge fluorescent PCR is engineered for low-burden post-drying environmental trailer swabs, group oral-fluid ropes, EDTA whole blood, and spleen/lymph node tissue homogenates.
Complete Technical Specifications: BioFortis ASFV Fluorescent PCR Reagent Kits
All three ASFV reagent formulations share identical closed-cartridge operation and ambient shipping stability across UPN0102 and UPN0104 platforms.
| Parameter | Specification | Note |
|---|---|---|
| Assay Variants | 1) Standard ASFV PCR; 2) ASFV p72/CD2v/MGF360 Triplex; 3) Genotype I / II Differential ASFV | Covers routine gate screening to strain differentiation |
| Compatible Analyzers | UPN0102 & UPN0104 Automated Fluorescent PCR Systems | QR-code auto-protocol recognition |
| Reagent Format | Pre-filled closed cartridge (extraction + amplification integrated) | Single-step loading; zero open-tube post-PCR steps |
| Transport & Storage | Vitrified room-temperature transport technology | Ships without dry-ice cold-chain logistics |
| Validated Sample Types | Environmental truck swabs, oral fluids, whole blood, tissue homogenates | Matches wash-bay and barn surveillance points |
| Internal Quality Control | Built-in endogenous/exogenous IC channel per reaction | Flags extraction failure or swab inhibition automatically |
Calculate Monthly ASFV Cartridge Consumption & Sampling Workflow
Civil, Electrical & Piping Interface Checklist
- Trailer Swab Sampling Points: Swab cab pedals, tailgate ramp hinges, lower deck slat seams, and wheel-well mudguards immediately after 70°C+ thermal drying completes.
- Oral-Fluid & Gilt Screening: Pool group oral-fluid cotton rope squeezes or collect EDTA whole blood during incoming replacement-gilt isolation before herd introduction.
- Ambient Inventory Handling: Store unopened sealed cartridge foil pouches in a dry room away from direct sunlight; verify lot expiration via printed QR label before loading.
Full AutoCAD (.DWG) and PDF foundation layouts are delivered within 5 business days of order confirmation.
Preventive Maintenance & Wear-Part Intervals
- Sample Prep Discipline: Always use fresh sterile disposable swabs and dedicated lysis tubes per truck bay to eliminate mechanical cross-transfer prior to cartridge sealing.
- Cartridge Disposal: Place completed closed cartridges directly into sealed biohazard waste bags without reopening caps, preserving zero-amplicon lab air quality.
- Quarterly QC Audit: Log internal-control (IC) Ct consistency across lots via the analyzer USB export archive for group biosecurity compliance reviews.
Need consolidated 12-month wear-part kits? See our Genuine Spare Parts Program
Four ASFV Testing Failures Solved by BioFortis Closed-Cartridge Kits
Lateral-flow antigen strips miss low-viral-load trailer swabs after washout
Fluorescent PCR amplification detects trace residual ASFV nucleic acids inside closed cartridges with built-in magnetic purification.
Single-gene p72 tests cannot distinguish wild-type ASFV from CD2v/MGF360 deletions
BioFortis Triplex and Genotype I/II differential cartridges resolve multiple target loci simultaneously inside one reaction.
Frozen liquid reagents spoil during international customs clearance delays
Vitrified room-temperature reagent stabilization maintains full analytical performance through ambient air freight without dry ice.
Uncontrolled extraction inhibition creates dangerous false-negative truck releases
Every cartridge contains an internal quality control channel verifying valid extraction and amplification before displaying a negative result.
From Sample Swab to Gate Clearance — Plus Hassle-Free Ambient Export Supply
Select Assay Variant
Choose Standard, p72/CD2v/MGF360 Triplex, or Genotype I/II based on surveillance need.
Ambient Air Dispatch
Cushioned export cartons ship by air courier worldwide with zero dry ice required.
Single-Step Swab Load
Mix swab in lysis buffer, transfer once into pre-filled cartridge, and snap cap closed.
Automated Closed PCR
Scan QR code on UPN0102 or UPN0104; extraction and amplification run automatically.
Gate Ticket & Archive
Verify IC-validated curve and print thermal clearance ticket before trailer dispatch.
Field Workflow: Post-Drying Livestock Truck Swabs & Quarantine Screening
Leading commercial swine hubs link physical 20 MPa washout and 70°C+ thermal drying directly to molecular ASFV release checks. Environmental swabs taken from dried multi-tier hog trailers and incoming gilt blood samples run side by side inside sealed BioFortis cartridges, establishing documented proof of negative status before gate entry.
What Quality & Export Documentation Ships with Every ASFV Reagent Batch?
Lot Certificate of Analysis (COA)
Batch sensitivity, specificity, and internal-control verification documentation per lot.
English Sampling & Loading SOP
Visual instructions for truck swabs, oral fluids, whole blood, and single-step cartridge loading.
Multiplex Channel Interpretation Guide
Clear threshold and target readout matrix for p72, CD2v, MGF360, Genotype I/II, and IC.
Non-Hazardous Ambient Air Declaration
Export packing list, commercial invoice, and ambient air-freight compliance paperwork.
Frequently Asked Questions About BioFortis ASFV Fluorescent PCR Reagent Kits
01Why is fluorescent PCR far more reliable than antigen rapid strips for ASFV truck swab screening?
02What is the difference between Standard ASFV, p72/CD2v/MGF360 Triplex, and Genotype I/II Differential kits?
03Do BioFortis ASFV PCR reagent kits require dry-ice cold-chain shipping?
04What sample types work with BioFortis closed-cartridge ASFV PCR kits?
05How does the built-in internal quality control prevent false-negative field reports?
06Which PCR analyzers are compatible with BioFortis pre-filled ASFV cartridges?
07How does closed-cartridge format prevent PCR contamination inside a farm room?
08Can farms combine different ASFV variants with PRRS or PEDV kits in one quarterly order?
09How much training does biosecurity gate staff need to run an ASFV PCR check?
10When should a farm test post-drying livestock trailers for ASFV?
Request ASFV PCR Reagent Pricing, Assay Datasheet & Analyzer Bundle
Specify your preferred ASFV assay variants (Standard, Triplex, Genotype I/II) and monthly testing volume to receive factory-direct pricing and analyzer bundle quotes within 12 business hours.
Related Equipment
Request a Quote & CAD Layout
Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.