Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
P17 · 17 kg Closed-Cartridge Gate PCR

UPN0102 Portable Veterinary PCR Analyzer

Waiting 48 hours for an external lab gives ASFV time to spread. UPN0102 weighs 17 kg and runs sealed-cartridge PCR right at your farm gate.

17 kg370×350×340 mm Benchtop
≤ 0.5°CTemp Control Accuracy
≥ 6°C/sFast Thermal Ramp
CV ≤ 3%Fluorescence Repeatability
UPN0102 Compact Fully Automated Veterinary Fluorescent PCR Analyzer
System Overview

Sealed-Cartridge PCR Replaces Three-Room Labs

BioFortis UPN0102 portable veterinary PCR analyzer integrates 3-stage magnetic-bead extraction and fluorescent amplification inside one sealed cartridge. Weighing 17 kg with ≤0.5°C thermal accuracy, CV ≤3% optics, and independent random-access bays, non-lab staff can verify urgent truck swabs at the gate.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
≥ 6°C/sHeating (≥4°C/s Cooling)
≤ 0.5°CAccuracy (≤1°C Uniform)
≤ 15 sFull Optical Scan Time
13.3-inchEnglish/Chinese Touch UI
Deployment Tiers

Gatehouse, Field Van, or 32-Sample Hub

Deploy UPN0102 at a single farm gatehouse, equip mobile vet teams, or compare with our 32-sample UPN0104 unit.

Tier 1 · Single Farm Gate

1× UPN0102 + Ambient ASFV Truck-Swab Gate Bundle

Compact 10–15 m² biosecurity gate station for 1,200–5,000 sow farms verifying dried livestock trucks and incoming gilts.

  • Independent modules run urgent truck swabs immediately
  • Zero cold-chain: vitrified ASFV cartridges ship at room temp
  • External USB thermal printer issues instant gate-release slips
Quote Gate Bundle
Tier 3 · High-Volume Upgrade

Compare with UPN0104 (31.5 kg, 32 Samples / Run)

For mega swine integrators or central C&D hubs running >30 swabs per shift, step up to or pair with UPN0104.

  • Doubles batch capacity to 32 samples per run (8-strip)
  • Runs identical pre-filled closed cartridges & English UI
  • Unified distributor training & spare-parts ecosystem
Compare UPN0102 vs 0104
How It Works

Built for Non-Lab Farm Staff

Sample-In Cartridge Stops Aerosol Leaks

Sample-In Cartridge Stops Aerosol Leaks

Open-lid extraction tubes flood small gate rooms with amplicon contamination. UPN0102 keeps lysis, magnetic-bead washing, and amplification sealed inside one disposable cartridge from start to trash.

1-StepSingle Pipette Load
0 AerosolSealed Cartridge
Test One Urgent Truck Without Waiting

Test One Urgent Truck Without Waiting

Drivers waiting outside the gatehouse cannot sit three hours until 32 swabs pile up. Independent modules start each dried-truck swab on arrival and print a negative ticket via USB.

Random AccessUrgent Swabs
AmbientNo Dry-Ice Shipping
Scan the Cartridge QR Code and Press Run

Scan the Cartridge QR Code and Press Run

Staff never type thermal cycles manually on small buttons. Scan the sealed tube barcode to load parameters automatically on the 13.3-inch bilingual screen across swine and ruminant assays.

13.3-inchBilingual Touch UI
900 VAStandard Bench Power
System Layout

Four Subsystems Inside UPN0102

3-Stage Magnetic-Bead Extractor

Automates lysis, binding, washing, and elution inside the closed reagent tube.

Rapid Thermal Block (≥6°C/s)

40–95°C cycling with ≤0.5°C accuracy and ≤1°C uniformity across wells.

UPN0102 Compact Fully Automated Veterinary Fluorescent PCR Analyzer structural breakdown
Low-Noise Fluorescence Optics

≤15 s full-channel scan delivering CV ≤3% repeatability and CV ≤5% precision.

13.3" Touch UI & Thermal Printer

QR-code assay loading, English/Chinese interface, and USB audit ticket export.

Want Demo Video, Kit Menu & Air-Freight Quote? Request a live run video, full swine/ruminant pathogen list, and door-to-door air quote within 12 hours.
Technical Specifications

UPN0102 Technical Specifications

Verified factory specifications for the BioFortis UPN0102 compact automated fluorescent PCR system.

ParameterSpecificationNote
ModelUPN0102Compact benchtop all-in-one closed-cartridge PCR analyzer
Dimensions (W × D × H)370 × 350 × 340 mmFits easily inside a 10–15 m² farm gatehouse or mobile van
Weight17 kgField-portable single-person benchtop deployment
Rated Power900 VA (AC 240V / 50Hz, T5AL 250V)Standard bench outlet; UPS backup recommended for rural sites
Temp Range & Accuracy40–95°C | ≤0.5°C accuracy | ≤1°C uniformityLab-grade thermal control for multiplex swine assays
Thermal Ramp RateHeating ≥ 6°C/s | Cooling ≥ 4°C/sAccelerates amplification turnaround at farm gates
Fluorescence OpticsScan ≤ 15 s | Repeatability CV ≤ 3% | Precision CV ≤ 5%High-sensitivity detection on low-load truck environmental swabs
UI & Peripherals13.3-inch touchscreen, English/Chinese UI, USB + external thermal printerQR-code cartridge entry with automated curve reporting
Sizing & Site Prep

Estimate Monthly Swabs & Cost Savings

Interactive Diagnostics Tool

On-Farm PCR Screening Throughput & Analyzer Selector

Calculate weekly swab volume and determine whether the UPN0102 compact or UPN0104 high-throughput analyzer matches your farm biosecurity schedule.

Weekly Screening Volume--
Monthly Reagent Kit Demand--
Recommended Platform--
“Put a 17 kg closed-cartridge PCR unit inside the gatehouse so every truck clears the gate with a printed negative swab ticket.”
BioFortis Molecular Biosecurity Team
Common Field Problems

Four On-Farm Testing Bottlenecks Removed

Field Problem

24–72 Hour External Lab Turnaround Delays

How BioFortis Solves It

On-site automated PCR delivers actionable ASFV/PEDV decisions right at the farm gate.

Field Problem

Rapid Antigen Strips Missing Low-Load Swabs

How BioFortis Solves It

Fluorescent PCR with CV ≤3% optics detects trace viral DNA that lateral-flow strips miss.

Field Problem

Aerosol False Positives in Compact Rooms

How BioFortis Solves It

Closed-tube extraction and amplification eliminate open-lid amplicon contamination.

Field Problem

Waiting Hours to Fill a 32-Sample Batch

How BioFortis Solves It

Independent detection modules run single urgent truck swabs immediately upon arrival.

Delivery Process

From Assay Selection to Gate Screening

01

Assay Menu Selection

Choose ASFV, PRRS/PEDV, FMDV, or ruminant vitrified reagent kits.

Day 1
02

Bundle Configuration

Pair UPN0102 with swab kits, mini centrifuge/lysis tools & thermal printer.

Day 2–3
03

Thermal & Optical FAT

Factory-verify ≤0.5°C accuracy and CV ≤3% optical precision.

Week 2
04

Ambient Air Freight

Ship 17 kg flight-cased analyzer + room-temp kits with zero dry ice.

Air / Sea
05

2-Hour Remote Training

Train farm biosecurity staff via live English video walkthrough.

2-Hr Go-Live
Verify Every Dried Truck Before Entry
Field Track Record

Verify Every Dried Truck Before Entry

Farms running BioFortis 20 MPa wash bays and 700–800 kW thermal drying chambers use UPN0102 right beside the clean exit yard to verify negative ASFV swabs before gates open.

Testing & Export Docs

Calibration Sheets, Illustrated SOP & Shipping Docs

DOC-01

Thermal & Optical Calibration Report

Factory test sheet verifying ≤0.5°C accuracy and CV ≤3% fluorescence.

Included
DOC-02

English Operator & Swab SOP

Illustrated step-by-step truck swabbing, cartridge loading & curve reading.

Included
DOC-03

Swine & Ruminant Kit Catalog

Complete compatible menu covering ASFV, PRRS, PEDV, FMDV & cattle/sheep.

Included
DOC-04

Export Customs & 12-Month Support

Export invoice, packing list, ambient shipping docs & remote vet support.

Included
10 Common Questions

Common Questions on UPN0102 Farm PCR

01Do farm biosecurity staff need molecular biology training to operate UPN0102?
No. Because three-stage magnetic-bead extraction, purification, and fluorescence PCR run automatically inside pre-filled closed cartridges, trained farm staff only load the swab lysate, scan the QR code, and tap Start on the 13.3-inch English touchscreen.
02How does closed-cartridge PCR prevent aerosol contamination in a small farm room?
Nucleic acid extraction and amplification remain permanently sealed inside the single-use cartridge. Because technicians never open amplified PCR tubes, amplicon carryover false positives are eliminated without needing a three-room negative-pressure lab.
03Can UPN0102 test an urgent livestock truck swab immediately without waiting for a batch?
Yes. UPN0102 features independent detection modules that support random-access urgent testing so gate staff can run a single dried hog trailer immediately rather than waiting to accumulate a full plate.
04How should we choose between the 17 kg UPN0102 and the 31.5 kg UPN0104?
Choose UPN0102 (17 kg, 900 VA) for single commercial pig farms, gatehouses, and mobile veterinary vans needing compact random-access screening. Choose UPN0104 (31.5 kg, 1,800 VA) for mega swine integrators or regional C&D hubs running up to 32 samples per run.
05Do BioFortis reagent kits for UPN0102 require frozen dry-ice shipping?
No. Our pre-filled reagent cartridges use ambient-temperature vitrification technology, allowing standard room-temperature air freight to Southeast Asia, Africa, and Latin America without cold-chain spoilage.
06Which swine and livestock pathogens can UPN0102 detect?
UPN0102 runs our full catalog of swine assays (ASFV standard, p72/CD2v/MGF360 triplex, Genotype I/II, PRRS NA/EU/HP, PEDV/TGEV/PDCoV/PoRV, FMDV/SVA, PRV gE, CSFV, and PCV2/3) plus cattle and sheep panels.
07How accurate is the thermal and optical system inside this 17 kg benchtop unit?
UPN0102 delivers laboratory-grade specs: 40–95°C cycling at ≥6°C/s heating and ≥4°C/s cooling, ≤0.5°C temperature control accuracy, ≤1°C uniformity, ≤15 s optical scan, and fluorescence repeatability CV ≤3%.
08Does UPN0102 print physical test reports for truck gate-release records?
Yes. UPN0102 includes a USB interface supporting an external thermal printer so biosecurity gates can attach a printed negative PCR audit slip to each truck's wash-and-dry clearance log.
09What electrical power is required to run UPN0102 on a remote farm?
UPN0102 draws 900 VA on standard AC 240V / 50Hz power (T5AL 250V fuse). On rural farms with unstable power grids, we recommend connecting through a compact 1,500 VA pure-sine UPS.
10How does BioFortis support operator training after air-freight delivery?
Every UPN0102 ships with an illustrated English SOP and includes live 2-hour remote video commissioning and swab-workflow training with our veterinary support specialists.
Talk to an Engineer

Request UPN0102 Pricing & Reagent Menu

Share your weekly truck swabs and herd count to get analyzer pricing and room-temperature cartridge options.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.