Full-Site Centralized Low-Pressure Disinfection & Misting System (22 kW)
BioFortis P08 Full-Site Centralized Low-Pressure Disinfection System delivers automated, constant-pressure disinfectant distribution across corridors, loading chutes, and empty barns—combining ≤5 bar (≤20 T/h) misting and ≤18 bar (≤12 T/h) spray modes with one-duty/one-standby pump redundancy.

Why Do Commercial Swine Farms Deploy Dedicated Low-Pressure Misting Disinfection Networks Alongside High-Pressure Wash Lines?
BioFortis P08 Full-Site Centralized Low-Pressure Disinfection Systems automatically mix concentrated disinfectant to exact target ratios and cycle pressurized solution through corridors, loading chutes, and empty barns on programmable time slots. Dual operating modes (≤5 bar at ≤20 T/h and ≤18 bar at ≤12 T/h) plus duty-standby pump redundancy guarantee uninterrupted biosecurity coverage during peak African Swine Fever outbreaks.
Which Centralized Disinfection Network Tier Matches Your Farm Layout?
Match pressure mode, zone solenoid count, and chemical tank integration to your swine or poultry facility's daily biosecurity schedule.
≤5 Bar Corridor & Loading Chute Misting Network
Automated time-slotted overhead misting across farm corridors, pig-loading ramps, and entry passages.
- Up to 20 T/h flow capacity for rapid full-zone coverage
- Programmable shift & night-time timed cycling
- Eliminates manual backpack sprayer labor & blind spots
Dual-Mode Station (≤5 Bar Misting + ≤18 Bar Spray)
Complete 22 kW VFD station feeding both automated overhead mist nozzles and manual empty-barn spray wands.
- Switches cleanly between ≤5 bar (20 T/h) & ≤18 bar (12 T/h)
- One-duty / one-standby pump backup prevents outage
- Auto concentrate mixing eliminates bucket dilution error
Integrated Wash + Disinfect + Batch Dosing Plant
Combines P08 disinfection station with P07 20 MPa high-pressure cleaning and P15 electronic tank dosing.
- Automated low-level tank refill with exact ratios
- Full VFD, low-level, overpressure & dry-run alarms
- Proven across multi-site commercial farms in Vietnam
What Engineering Features Guarantee Uninterrupted, Accurate Farm-Wide Disinfection?
Automated Disinfectant Mixing Eliminates Manual Bucket Errors
Manual bucket pouring into large holding tanks produces weak, ineffective solutions or corrosive over-concentration. BioFortis P08 pairs with automated proportioning to maintain exact chemical dilutions before feeding zone manifolds.
One-Duty / One-Standby Pump Redundancy with VFD Control
A single-pump failure during a regional ASFV alert leaves an entire site exposed. BioFortis equips every P08 station with dual corrosion-resistant pumps under VFD speed control so standby capacity engages seamlessly without interrupting zone schedules.
Programmable Time-Slotted Zone Cycling Across Barns & Corridors
PLC-controlled solenoid zone valves cycle disinfectant automatically through loading chutes, transfer corridors, and empty barns on fixed intervals—delivering consistent 24/7 contact coverage with zero manual valve turning.
Inside the BioFortis P08 Disinfection Skid: Four Critical Sub-Assemblies
Corrosion-resistant twin pumps ensure uninterrupted operation during maintenance or outbreaks.
Variable-frequency drive with low-level, overpressure relief, and water-shortage alarms.
Feeds both ≤5 bar (≤20 T/h) misting lines and ≤18 bar (≤12 T/h) manual spray wands.
Automates time-slotted disinfection across corridors, loading ramps, and empty rooms.
Complete Technical Specifications: P08 Full-Site Low-Pressure Disinfection System
Verified factory specifications for the BioFortis P08 22 kW centralized disinfection station.
| Parameter | Specification | Note |
|---|---|---|
| Rated Voltage | AC 380V / 50Hz | 3-phase industrial supply (60Hz configurable on export order) |
| Max Electric Power | 22 kW | VFD-driven constant pressure control |
| Low-Pressure Mode | ≤ 5 bar | Flow ≤ 20 T/h | Engineered for overhead misting nozzles and corridor fogging |
| High-Pressure Mode | ≤ 18 bar | Flow ≤ 12 T/h | Engineered for manual spray-wand terminal barn disinfection |
| Pump Configuration | One duty, one standby backup redundancy | Automatic failover prevents biosecurity downtime |
| Built-In Protections | VFD speed control, low-level, overpressure relief, water shortage | Protects pumps and pipelines during unattended timed cycles |
Calculate Disinfectant Concentration, Zone Flow & Utility Requirements
Civil, Electrical & Piping Interface Checklist
- Supply AC 380V 3-phase power (22 kW max) inside a dry, ventilated chemical and pump utility room.
- Pair with a chemical-grade PE or stainless holding tank equipped with low-level float interlocks.
- Divide barn wings into balanced solenoid zones matched to ≤20 T/h (low mode) or ≤12 T/h (high mode).
Full AutoCAD (.DWG) and PDF foundation layouts are delivered within 5 business days of order confirmation.
Preventive Maintenance & Wear-Part Intervals
- Alternate duty and standby pump run hours monthly via the PLC to keep both mechanical seals conditioned.
- Flush zone headers with clean water before switching between incompatible disinfectant chemistries.
- Inspect misting nozzle filters and overpressure relief valves every 90 days.
Need consolidated 12-month wear-part kits? See our Genuine Spare Parts Program
Four Barn Disinfection Failure Modes Eliminated by BioFortis P08
Outbreak-Peak Single-Pump Failure
One-duty/one-standby pump redundancy keeps full-site disinfection active even if a pump requires service.
Manual Bucket Concentration Drift
Automated concentrate proportioning eliminates weak under-dosed mixes and corrosive over-dosing.
Missed Night & Loading-Ramp Cycles
Programmable time-slotted zone cycling runs automatically on schedule without relying on manual labor.
Dry-Run Burnout & Line Bursting
VFD control plus low-level, water-shortage, and overpressure relief alarms protect unattended runs.
How BioFortis Delivers & Commissions a Full-Site Barn Disinfection Network
Zone & Flow Mapping
Divide corridors, loading chutes, and barns into timed disinfection zones.
P&ID & Solenoid CAD
Finalize holding tank sizing, dual-mode headers, and nozzle spacing.
Dual-Mode Factory FAT
Test both ≤5 bar and ≤18 bar curves, VFD failover, and safety alarms.
Export Containerization
Ship pre-wired 22 kW skid, solenoids, nozzles, and seal kits together.
PLC Timer Commissioning
Configure zone schedules remotely or on site with bilingual SOP training.
Field Validation: Centralized Disinfection & Dosing Pump Rooms in Vietnam
Deployed across 3 commercial swine facilities for a Leading Integrated Commercial Swine Producer in Vietnam, BioFortis centralized dosing and disinfection rooms standardize chemical preparation and automated delivery across high-density breeding and finishing sites.
What Engineering Documentation Ships with Every P08 Disinfection Station?
Dual-Pressure & VFD FAT Report
Verified ≤5 bar (20 T/h) and ≤18 bar (12 T/h) test curves plus failover check.
Zone P&ID & Wiring Diagrams
Complete piping, solenoid valve wiring, and AC 380V electrical schematics.
English PLC Scheduling SOP
Step-by-step zone timer programming, chemistry flush, and safety guide.
Export Docs & 12-Month Spare BOM
Customs pack plus recommended mechanical seals, solenoids, and misting tips.
Frequently Asked Questions About Centralized Farm Misting Disinfection Systems
01How does the P08 low-pressure disinfection system differ from the P07 high-pressure cleaning system?
02Why does BioFortis P08 include both ≤5 bar (≤20 T/h) and ≤18 bar (≤12 T/h) modes?
03How does one-duty/one-standby pump redundancy protect a pig farm during an outbreak?
04How does programmable time-slotted zone cycling work?
05Which farm disinfectants are compatible with BioFortis P08 wetted components?
06What safety protections prevent pump damage during unattended timed runs?
07Can P08 integrate with the P15 Electronic Standard Dosing System?
08Is the P08 system also suitable for commercial poultry broiler and layer houses?
09What electrical power is required for export installations?
10Do you supply the complete zone piping, solenoid valves, and misting nozzles?
Request a Zone Disinfection P&ID & Quote for the BioFortis P08 System
Share your building count, corridor length, and preferred disinfection schedule to receive a custom P08 dual-mode proposal.
Related Equipment
Request a Quote & CAD Layout
Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.