Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Automated Zone Misting & Spray Disinfection

Full-Site Centralized Low-Pressure Disinfection & Misting System (22 kW)

BioFortis P08 Full-Site Centralized Low-Pressure Disinfection System delivers automated, constant-pressure disinfectant distribution across corridors, loading chutes, and empty barns—combining ≤5 bar (≤20 T/h) misting and ≤18 bar (≤12 T/h) spray modes with one-duty/one-standby pump redundancy.

≤ 5 bar / 20 T/hLow-Pressure Misting
≤ 18 bar / 12 T/hSpray-Wand Mode
22 kWAC 380V VFD Station
1 + 1 PumpsDuty-Standby Backup
Full-Site Centralized Low-Pressure Disinfection System
System Overview

Why Do Commercial Swine Farms Deploy Dedicated Low-Pressure Misting Disinfection Networks Alongside High-Pressure Wash Lines?

BioFortis P08 Full-Site Centralized Low-Pressure Disinfection Systems automatically mix concentrated disinfectant to exact target ratios and cycle pressurized solution through corridors, loading chutes, and empty barns on programmable time slots. Dual operating modes (≤5 bar at ≤20 T/h and ≤18 bar at ≤12 T/h) plus duty-standby pump redundancy guarantee uninterrupted biosecurity coverage during peak African Swine Fever outbreaks.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
≤ 20 T/hHigh-Volume Zone Misting
≤ 18 barPressurized Spray Mode
1 + 1 BackupZero-Downtime Redundancy
4-LayerVFD & Hydraulic Safety
Deployment Tiers

Which Centralized Disinfection Network Tier Matches Your Farm Layout?

Match pressure mode, zone solenoid count, and chemical tank integration to your swine or poultry facility's daily biosecurity schedule.

Tier 1 · Overhead Misting

≤5 Bar Corridor & Loading Chute Misting Network

Automated time-slotted overhead misting across farm corridors, pig-loading ramps, and entry passages.

  • Up to 20 T/h flow capacity for rapid full-zone coverage
  • Programmable shift & night-time timed cycling
  • Eliminates manual backpack sprayer labor & blind spots
Quote Misting Network
Tier 3 · Multi-Site Turnkey

Integrated Wash + Disinfect + Batch Dosing Plant

Combines P08 disinfection station with P07 20 MPa high-pressure cleaning and P15 electronic tank dosing.

  • Automated low-level tank refill with exact ratios
  • Full VFD, low-level, overpressure & dry-run alarms
  • Proven across multi-site commercial farms in Vietnam
Request Full-Site P&ID
How It Works

What Engineering Features Guarantee Uninterrupted, Accurate Farm-Wide Disinfection?

Automated Disinfectant Mixing Eliminates Manual Bucket Errors

Automated Disinfectant Mixing Eliminates Manual Bucket Errors

Manual bucket pouring into large holding tanks produces weak, ineffective solutions or corrosive over-concentration. BioFortis P08 pairs with automated proportioning to maintain exact chemical dilutions before feeding zone manifolds.

Exact RatioAuto Proportioning
Zero SpillClosed Transfer
One-Duty / One-Standby Pump Redundancy with VFD Control

One-Duty / One-Standby Pump Redundancy with VFD Control

A single-pump failure during a regional ASFV alert leaves an entire site exposed. BioFortis equips every P08 station with dual corrosion-resistant pumps under VFD speed control so standby capacity engages seamlessly without interrupting zone schedules.

1 + 1 PumpsDuty-Standby
22 kWVFD Regulated
Programmable Time-Slotted Zone Cycling Across Barns & Corridors

Programmable Time-Slotted Zone Cycling Across Barns & Corridors

PLC-controlled solenoid zone valves cycle disinfectant automatically through loading chutes, transfer corridors, and empty barns on fixed intervals—delivering consistent 24/7 contact coverage with zero manual valve turning.

Timed ZonesAuto Cycling
4 ProtectionsLevel & Pressure
System Layout

Inside the BioFortis P08 Disinfection Skid: Four Critical Sub-Assemblies

Duty-Standby Pump Pair

Corrosion-resistant twin pumps ensure uninterrupted operation during maintenance or outbreaks.

VFD & 4-Layer Safety Panel

Variable-frequency drive with low-level, overpressure relief, and water-shortage alarms.

Full-Site Centralized Low-Pressure Disinfection System structural breakdown
Dual-Pressure Output Header

Feeds both ≤5 bar (≤20 T/h) misting lines and ≤18 bar (≤12 T/h) manual spray wands.

Programmable Zone Solenoids

Automates time-slotted disinfection across corridors, loading ramps, and empty rooms.

Need a Zone Disinfection P&ID for Your Pig Barns or Poultry Houses? Send your corridor and building layout—our engineers size zone flows, nozzle spacing, and return a P08 FOB/CIF quote within 12 hours.
Technical Specifications

Complete Technical Specifications: P08 Full-Site Low-Pressure Disinfection System

Verified factory specifications for the BioFortis P08 22 kW centralized disinfection station.

ParameterSpecificationNote
Rated VoltageAC 380V / 50Hz3-phase industrial supply (60Hz configurable on export order)
Max Electric Power22 kWVFD-driven constant pressure control
Low-Pressure Mode≤ 5 bar | Flow ≤ 20 T/hEngineered for overhead misting nozzles and corridor fogging
High-Pressure Mode≤ 18 bar | Flow ≤ 12 T/hEngineered for manual spray-wand terminal barn disinfection
Pump ConfigurationOne duty, one standby backup redundancyAutomatic failover prevents biosecurity downtime
Built-In ProtectionsVFD speed control, low-level, overpressure relief, water shortageProtects pumps and pipelines during unattended timed cycles
Sizing & Site Prep

Calculate Disinfectant Concentration, Zone Flow & Utility Requirements

Interactive Dosing Tool

Disinfectant & Medicator Proportioning Calculator

Calculate exact chemical concentrate consumption and select the right BioFortis proportional medicator for your barn pipeline.

Concentrate Injection Rate--
Daily Chemical Requirement--
Recommended Medicator--
“High-frequency, accurately dosed, zero-shortcut automated zone disinfection is the only reliable way to hold the aerosol biosecurity line across busy pig farm corridors and loading chutes.”
BioFortis Farm Biosecurity Systems Engineering
Common Field Problems

Four Barn Disinfection Failure Modes Eliminated by BioFortis P08

Field Problem

Outbreak-Peak Single-Pump Failure

How BioFortis Solves It

One-duty/one-standby pump redundancy keeps full-site disinfection active even if a pump requires service.

Field Problem

Manual Bucket Concentration Drift

How BioFortis Solves It

Automated concentrate proportioning eliminates weak under-dosed mixes and corrosive over-dosing.

Field Problem

Missed Night & Loading-Ramp Cycles

How BioFortis Solves It

Programmable time-slotted zone cycling runs automatically on schedule without relying on manual labor.

Field Problem

Dry-Run Burnout & Line Bursting

How BioFortis Solves It

VFD control plus low-level, water-shortage, and overpressure relief alarms protect unattended runs.

Delivery Process

How BioFortis Delivers & Commissions a Full-Site Barn Disinfection Network

01

Zone & Flow Mapping

Divide corridors, loading chutes, and barns into timed disinfection zones.

Day 1–2
02

P&ID & Solenoid CAD

Finalize holding tank sizing, dual-mode headers, and nozzle spacing.

Day 3–7
03

Dual-Mode Factory FAT

Test both ≤5 bar and ≤18 bar curves, VFD failover, and safety alarms.

Week 3–4
04

Export Containerization

Ship pre-wired 22 kW skid, solenoids, nozzles, and seal kits together.

FOB / CIF
05

PLC Timer Commissioning

Configure zone schedules remotely or on site with bilingual SOP training.

24h SLA
Field Validation: Centralized Disinfection & Dosing Pump Rooms in Vietnam
Field Track Record

Field Validation: Centralized Disinfection & Dosing Pump Rooms in Vietnam

Deployed across 3 commercial swine facilities for a Leading Integrated Commercial Swine Producer in Vietnam, BioFortis centralized dosing and disinfection rooms standardize chemical preparation and automated delivery across high-density breeding and finishing sites.

Testing & Export Docs

What Engineering Documentation Ships with Every P08 Disinfection Station?

DOC-01

Dual-Pressure & VFD FAT Report

Verified ≤5 bar (20 T/h) and ≤18 bar (12 T/h) test curves plus failover check.

Included
DOC-02

Zone P&ID & Wiring Diagrams

Complete piping, solenoid valve wiring, and AC 380V electrical schematics.

Included
DOC-03

English PLC Scheduling SOP

Step-by-step zone timer programming, chemistry flush, and safety guide.

Included
DOC-04

Export Docs & 12-Month Spare BOM

Customs pack plus recommended mechanical seals, solenoids, and misting tips.

Included
10 Common Questions

Frequently Asked Questions About Centralized Farm Misting Disinfection Systems

01How does the P08 low-pressure disinfection system differ from the P07 high-pressure cleaning system?
P07 uses up to 20 MPa mechanical pressure to strip dried manure and biofilm during empty-barn washouts. P08 operates at ≤5 bar to ≤18 bar specifically to mix and distribute calibrated liquid disinfectant across corridors, loading ramps, and sanitized rooms.
02Why does BioFortis P08 include both ≤5 bar (≤20 T/h) and ≤18 bar (≤12 T/h) modes?
Overhead misting nozzles along corridors and barns require high flow at low pressure (≤5 bar, up to 20 T/h) for gentle, uniform fogging. Manual spray wands used for terminal room disinfection need higher reach and atomization (≤18 bar, up to 12 T/h)—one P08 skid handles both.
03How does one-duty/one-standby pump redundancy protect a pig farm during an outbreak?
If the primary duty pump experiences seal wear or trips during a critical ASFV or PEDV alert, the standby pump takes over immediately so timed corridor and loading-chute disinfection never stops while maintenance is performed.
04How does programmable time-slotted zone cycling work?
The central PLC opens and closes zone solenoid valves in sequence according to preset schedules—for example, misting loading chutes after every truck dispatch and corridors every 4 hours—without workers manually walking valves.
05Which farm disinfectants are compatible with BioFortis P08 wetted components?
P08 pump heads, seals, and manifolds are engineered to withstand common agricultural disinfectants including glutaraldehyde, quaternary ammonium blends, potassium peroxymonosulfate, and organic acids when flushed cleanly between chemistry changes.
06What safety protections prevent pump damage during unattended timed runs?
Every P08 station includes VFD speed control, chemical tank low-level alarms, incoming water-shortage shutdown, and mechanical overpressure relief valves so unattended night cycles cannot run dry or burst zone piping.
07Can P08 integrate with the P15 Electronic Standard Dosing System?
Yes. Pairing P15 with the P08 holding tank automates batch refill at 1:50–1:1000 ratios whenever tank float switches drop, eliminating manual bucket mixing completely.
08Is the P08 system also suitable for commercial poultry broiler and layer houses?
Yes. Commercial poultry operations use P08's ≤5 bar overhead misting and ≤18 bar spray modes to saturate ceiling beams, drinkers, and air inlets evenly between flock cycles for Avian Influenza and Salmonella control.
09What electrical power is required for export installations?
P08 requires AC 380V / 50Hz three-phase power up to 22 kW max load. BioFortis configures 60Hz VFD drives and motors for Latin American and Southeast Asian 60Hz grids on export orders.
10Do you supply the complete zone piping, solenoid valves, and misting nozzles?
Yes. We provide complete turnkey packages including the 22 kW duty-standby skid, holding tank controls, zone solenoid manifolds, stainless misting nozzles, and 12-month spare-part kits.
Talk to an Engineer

Request a Zone Disinfection P&ID & Quote for the BioFortis P08 System

Share your building count, corridor length, and preferred disinfection schedule to receive a custom P08 dual-mode proposal.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.