Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Zero-Emission Induction Thermal Wash

120 kW Electric Hot Water Pressure Washer & Electromagnetic Boiler (0–30 MPa)

BioFortis P11 is an electric hot water pressure boiler and 120 kW electromagnetic heater for electric hot water pressure washer lines, delivering 0–30 L/min of PID-controlled hot water (up to 100°C at 0–30 MPa) with zero exhaust flue, zero fuel storage permits, water-electricity isolation, and scale-resistant electromagnetic induction heating.

120 kWElectromagnetic Induction
0–30 MPaPump-Downstream Rating
0–30 L/minInstant PID Flow
Zero FlueIndoor Zero Emissions
120 kW Electromagnetic High-Pressure Hot Water Boiler
System Overview

Why Do Modern Indoor Pig Farms and Food Facilities Choose Electromagnetic Induction Over Resistive or Diesel Boilers?

BioFortis P11 120 kW Electromagnetic High-Pressure Hot Water Boilers heat pressurized 0–30 MPa water up to 100°C via non-contact electromagnetic induction—completely isolating water from electrical coils while resisting mineral scale far better than immersed resistive rods. With zero combustion exhaust and zero fuel tank permits, P11 deploys safely inside enclosed multi-story swine farms and strict environmental zones. Engineered as an electric hot water high pressure washer module and hot water pressure washer electric heat source for enclosed indoor plant rooms.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
Zero FlueNo Exhaust or Fuel Tank
0–30 MPaHigh-Pressure Direct
PID ControlSteady 60–100°C Shift
Anti-ScaleInduction Magnetic Field
Deployment Tiers

Which Electromagnetic Hot Water Deployment Tier Fits Your Facility?

Deploy single or multi-floor 120 kW induction boilers where clean electric power is available and indoor zero-emission compliance is mandatory.

Tier 1 · Indoor Utility Room

1× P11 120 kW Boiler (0–30 L/min, 1–2 Hot Lances)

Zero-emission hot-water upgrade for enclosed barn utility rooms, food-grade wash bays, or urban quarantine stations.

  • No exhaust chimney, no diesel tank, no fuel odor
  • True 0–30 MPa downstream rating protects plunger pumps
  • PID digital control locks steady 60–80°C barn wash temp
Quote Single P11
Tier 3 · High + Low Dual Electric

P11 (120 kW High-Pressure) + P12 (20 kW Low-Pressure)

Complete all-electric farm thermal ecosystem covering 20 MPa barn scouring plus 0.1–0.6 MPa staff showers and dosing.

  • Eliminates diesel deliveries across the entire swine site
  • Matches solar/green-grid farm sustainability mandates
  • Unified AC 380V electrical engineering documentation
Request All-Electric Plan
System Layout

Inside the BioFortis P11 Electromagnetic Boiler: Four Safety & Thermal Modules

Isolated 30 MPa Induction Core

Non-contact electromagnetic coils heat the pressure vessel externally with zero electrical contact to water.

120 kW Industrial IGBT Driver

High-efficiency power electronics convert AC 380V into rapid, scale-resistant induction heat.

120 kW Electromagnetic High-Pressure Hot Water Boiler structural breakdown
PID Temp & Dry-Run Interlock

Locks 60–100°C setpoints with automatic flow, over-temperature, and overload shutdown.

Moisture-Sealed AC 380V Cabinet

Industrial electrical enclosure engineered for humid farm plant rooms.

How It Works

Three Engineering Advantages of Electromagnetic Induction in Commercial Swine Sanitation

Zero Exhaust Flues, Zero Fuel Tanks, Zero Combustion Emissions

Zero Exhaust Flues, Zero Fuel Tanks, Zero Combustion Emissions

Modern multi-story pig farms and eco-regulated agricultural parks prohibit indoor fuel burners and diesel storage tanks. P11 operates 100% electrically inside closed mechanical rooms with zero fumes, soot, or fire-permit delays.

0 EmissionsIndoor Compliant
120 kWClean Electric
Water-Electricity Isolation & Scale-Resistant Induction Heating

Water-Electricity Isolation & Scale-Resistant Induction Heating

Immersed resistive heating rods collect insulating mineral scale in farm well water, overheat, and risk electrical leakage. Electromagnetic induction heats the pressure tube wall magnetically from outside—keeping water and electricity physically separated while resisting scale buildup.

IsolatedWater & Power
Anti-ScaleLonger Service Life
Stable PID Temperature Control Across Long Wash Shifts

Stable PID Temperature Control Across Long Wash Shifts

Precision PID power modulation tracks incoming water flow (0–30 L/min) continuously so outlet temperature stays locked at your exact setpoint—60–80°C for farrowing slats or up to 100°C for heavy grease—without thermal spikes.

PID LoopSteady Outlet Temp
0–30 MPaDirect Discharge
Verifying 380V Transformer Capacity for a Zero-Emission 120 kW Boiler? Request our P11 electrical load sheet, single-line diagram, and FOB/CIF quote—delivered by our engineering team within 12 hours.
Technical Specifications

Complete Technical Specifications: P11 120 kW Electromagnetic High-Pressure Boiler

Verified factory specifications for the BioFortis P11 zero-emission induction boiler.

ParameterSpecificationNote
Rated VoltageAC 380V / 50Hz3-phase industrial power (60Hz configurable on export order)
Energy SourceElectric (Electromagnetic Induction)Zero exhaust flue, zero fuel storage, water-electricity isolated
Max Power120 kWHigh electrothermal conversion efficiency with PID modulation
Working Pressure Range0–30 MPaConnects directly downstream of 20 MPa plunger pumps
Heating Flow Range0–30 L/minInstant-on heating with zero standby tank heat losses
Max Outlet Water Temp100°CStable PID control across continuous multi-hour wash shifts
Sizing & Site Prep

Verify 380V Electrical Capacity, Flow Sizing & Maintenance Schedule

Interactive Engineering Tool

Truck Wash & Thermal Drying Hub Sizing Calculator

Estimate required wash lanes, 700–800 kW drying chambers, daily water demand, and 380V electrical load for your biosecurity center.

Recommended Wash Bays (20 MPa)--
Recommended Drying Rooms--
Estimated Wash Water Demand--
Estimated Connected Load--
“Inside modern multi-story swine farms and eco-regulated facilities, water-isolated electromagnetic induction brings 100°C, 20 MPa thermal washout indoors—with zero flames, zero chimneys, and zero fuel-handling risk.”
BioFortis Clean Thermal Engineering Team
Common Field Problems

Four Electric Boiler Failures Eliminated by BioFortis Electromagnetic Design

Field Problem

Immersed Resistive Rods Scaling & Burning Out

How BioFortis Solves It

External electromagnetic induction resists mineral scale adherence and eliminates direct element burnout.

Field Problem

Insulation Breakdown & High-Pressure Shock Risk

How BioFortis Solves It

Physical water-electricity isolation keeps energized coils completely separated from pressurized wash water.

Field Problem

Indoor Exhaust & Fuel Tank Permit Rejections

How BioFortis Solves It

100% electric zero-emission operation deploys inside enclosed rooms with no flues or diesel tanks.

Field Problem

Massive Standby Tank Electricity Waste

How BioFortis Solves It

Instant-on PID heating draws 120 kW only while wash lances are actively flowing.

Delivery Process

How BioFortis Delivers & Commissions Your 120 kW Electromagnetic Boiler

01

Grid & Flow Check

Verify AC 380V transformer headroom, cable sizing, and wash gun flow.

Day 1–2
02

Single-Line & P&ID

Deliver electrical single-line diagram and pump-downstream piping CAD.

Day 3–6
03

30 MPa & 120 kW FAT

Hydro-test to 30 MPa and verify full-load PID thermal accuracy at factory.

Week 3
04

Export Containerization

Pack unit and spare sensor/fan kit in fumigation-free export crates.

FOB / CIF
05

Remote PID Setup

Guide local site electricians through wiring and 60–100°C setpoint tuning.

24h SLA
System Integration Proof: Pairing 120 kW Thermal Output with Centralized 20 MPa Pump Skids
Field Track Record

System Integration Proof: Pairing 120 kW Thermal Output with Centralized 20 MPa Pump Skids

BioFortis centralized 20 MPa high-pressure pumping stations operate across commercial swine sites in Southeast Asia, providing the exact cold-inlet, downstream-heated stainless piping architecture engineered for the P11 electromagnetic boiler.

Testing & Export Docs

What Engineering Documentation Ships with Every P11 Electromagnetic Boiler?

DOC-01

30 MPa & 120 kW Electrical FAT

Documented hydrostatic pressure test, insulation test, and PID thermal log.

Included
DOC-02

380V Single-Line & Piping CAD

DWG/PDF breaker sizing, cable gauge chart, and series piping layout.

Included
DOC-03

English PID & Safety Manual

Temperature programming, cooling-filter cleaning, and fault diagnostics.

Included
DOC-04

Export Docs & 12-Month Spare BOM

Customs pack plus flow switch, temperature probe, and cooling fan spares.

Included
11 Common Questions

Frequently Asked Questions About the P11 120 kW Electromagnetic High-Pressure Boiler

01How does electromagnetic induction resist scale better than immersed electric heating rods?
Immersed resistive rods create extreme localized hot spots directly in the water that bake calcium scale onto the element sheath. Electromagnetic induction heats the pressure tube uniformly from outside while high-frequency magnetic fields inhibit hard scale crystallization.
02Why is electromagnetic induction safer in wet farm utility rooms?
P11 maintains complete physical water-and-electricity separation: the energized induction coils wrap externally around an insulated heating chamber and never touch the pressurized wash water, drastically reducing electrical leakage risk.
03What is the difference between P11 (120 kW) and P12 (20 kW) electromagnetic boilers?
P11 is a 120 kW high-pressure boiler rated 0–30 MPa (0–30 L/min, 100°C) for 20 MPa barn and truck washout lines. P12 is a compact 20 kW low-pressure boiler rated 0.1–0.6 MPa (9 L/min at 65°C, max 85°C) for staff showers, hand gates, and warm disinfectant mixing.
04Does the P11 require an exhaust chimney or fuel storage permit?
No. P11 produces zero combustion exhaust, zero smoke, and zero fuel odor—making it ideal for enclosed multi-story pig buildings, indoor slaughterhouse plant rooms, and environmentally regulated zones.
05Why does P11 install downstream of the high-pressure pump at 0–30 MPa?
Heating water on the 0–30 MPa discharge side ensures only cold water enters the ceramic plunger pump, preventing heat damage to pump water seals while still delivering up to 100°C at the wash lance.
06What AC 380V electrical capacity is needed to run the P11 boiler?
At full 120 kW output on AC 380V three-phase power, P11 draws approximately 185–200 A. Sites should confirm transformer headroom and install a dedicated industrial breaker per our single-line diagram.
07How does PID control keep wash water temperature steady?
Built-in PID modulation adjusts induction power continuously as water flow varies between 0 and 30 L/min, holding your exact target (60–80°C for barns or 85–100°C for abattoirs) without temperature swings.
08When should a farm choose P11 Electric over P09 Diesel or P10 Natural Gas?
Choose P11 when ample 380V grid or solar power is available and indoor zero-emission operation is prioritized; choose P09 Diesel for off-grid farms; choose P10 Natural Gas when piped gas is available and up to 120 L/min flow is needed.
09Does P11 still benefit from an upstream water softener?
Yes. Even though induction resists scale far better than resistive rods, pairing P11 with an upstream water softener and sediment filter maximizes coil efficiency and protects your main plunger pump seals.
10Can P11 be built for AC 380V–480V / 60Hz grids?
Yes. Standard units ship in AC 380V / 50Hz, and BioFortis configures 60Hz power electronics for export regions on order.
11Why choose an electric hot water high pressure washer boiler over fuel-fired burners inside plant rooms?
An AC 380V induction hot water pressure washer electric system eliminates exhaust flues, soot, and on-site diesel tanks inside enclosed utility rooms while holding exact PID wash temperatures.
Talk to an Engineer

Request a 120 kW Electromagnetic Boiler Quote & Electrical Load Sheet

Share your site voltage, transformer capacity, and washout flow target to receive a P11 engineering proposal.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.