Integrated Farm Biosecurity: Wash · Disinfect · Dry · Detect
Precision Drinking-Line & Barn Dosing

Medium-Pressure Touchscreen Inline Water Medicator (0–10 Bar, 99.6% Accuracy)

BioFortis P14 Medium-Pressure Touchscreen Inline Water Medicator delivers up to 99.6% dosing accuracy across 0–10 bar pressurized pipelines—unaffected by barn water pressure swings—covering 1:50–1:1000 ratios at up to 3 L/min for swine drinking-water antibiotics, organic acids, and barn disinfection.

Up to 99.6%Dosing Precision
0–10 barInline Pressurized
1:50–1:1000Touchscreen Ratio
3 L/minAC 220V Output
Medium-Pressure Touchscreen Water Medicator (0–10 bar)
System Overview

Why Are Commercial Swine Farms Switching from Mechanical Piston Medicators to 99.6% Digital Inline Medicators?

BioFortis P14 Medium-Pressure Touchscreen Inline Water Medicators eliminate the pressure-sensitivity and fixed 1:128 sleeve limitations of mechanical water-driven piston injectors. Using external pulse water-meter feedback and direct digital touchscreen ratio entry (1:50–1:1000) across 0–10 bar, P14 holds up to 99.6% accuracy—preventing costly antibiotic overdosing and sub-therapeutic treatment failures.

Last reviewed: November 2026 · Engineering Specification Rev. 2.5
99.6%Digital Ratio Accuracy
0–10 barPressure-Swing Immune
3 L/minMax Chemical Output
Pulse + CommSCADA Monitoring Ready
Deployment Tiers

Which P14 Inline Water Medicator Setup Fits Your Pig Barn Watering & Disinfection Lines?

Deploy single-barn medication bypasses or multi-house SCADA-linked dosing networks across 0–10 bar livestock pipelines.

Tier 1 · Single Barn Line

Farrowing / Nursery Drinking-Water Medication Station

Dedicated bypass installation with external pulse water meter for antibiotics, electrolytes, vaccines, and organic acids.

  • 99.6% accuracy even at low piglet drinking flows
  • Touchscreen switches 1:50–1:1000 in seconds without sleeves
  • Plugs into standard AC 220V single-phase barn power
Quote Barn Medicator
Tier 3 · Multi-Barn SCADA

Group-Wide Connected Medication & Audit Network

Networked P14 units across multiple sow and nursery houses reporting live dosing volumes to central farm SCADA.

  • Remote communication port logs daily medication usage
  • Verifies exact dosage compliance across night shifts
  • Eliminates costly antibiotic waste across mega complexes
Request SCADA Spec
How It Works

What Engineering Features Guarantee 99.6% Dosing Accuracy Under Fluctuating Barn Pressure?

Pressure-Decoupled Electronic Precision Up to 99.6%

Pressure-Decoupled Electronic Precision Up to 99.6%

Mechanical water-driven piston medicators stall at low nursery flows and drift whenever booster pumps cycle. P14 reads exact line flow from an external pulse water meter and drives a precision 0–10 bar metering head—holding up to 99.6% accuracy regardless of pressure swings.

99.6%Dosing Precision
0–10 barLine Pressure
Instant Touchscreen Ratio Entry (1:50–1:1000) Eliminates Operator Error

Instant Touchscreen Ratio Entry (1:50–1:1000) Eliminates Operator Error

Switching from 1:200 antibiotics to 1:500 water acidifiers or 1:100 disinfectants takes seconds on the digital touchscreen—eliminating mechanical sleeve adjustments and error-prone manual stock-bucket recalculations.

1:50–1:1000Direct Touch Entry
3 L/minMax Dosing Flow
External Pulse Water Meter & Remote SCADA Telemetry Support

External Pulse Water Meter & Remote SCADA Telemetry Support

Built-in pulse-meter inputs and remote communication ports integrate P14 seamlessly into modern swine barn automation, giving herd veterinarians verifiable consumption records per barn.

AC 220VPlug & Play
SCADA PortRemote Audit
System Layout

Inside the BioFortis P14 Inline Water Medicator: Four Precision Sub-Assemblies

0–10 Bar Chemical-Resistant Head

Delivers up to 3 L/min of antibiotics, organic acids, or disinfectants against line pressure.

Digital Touchscreen HMI

Direct 1:50–1:1000 ratio input with live flow display and alarm indicators.

Medium-Pressure Touchscreen Water Medicator (0–10 bar) structural breakdown
Pulse Water Meter Interface

Syncs chemical strokes 1:1 with real drinking-line flow for 99.6% precision.

Remote Comm & AC 220V Module

Links dosing telemetry to central farm SCADA with moisture-sealed electronics.

Ready to Replace Drifting Mechanical Medicators with 99.6% Touchscreen Accuracy? Request our bypass plumbing diagram, pulse water-meter sizing guide, and P14 FOB/CIF quote within 12 hours.
Technical Specifications

Complete Technical Specifications: P14 Medium-Pressure Touchscreen Water Medicator

Verified factory specifications for the BioFortis P14 inline proportional medicator.

ParameterSpecificationNote
Rated VoltageAC 220V / 50HzSingle-phase barn power (60Hz configurable on export order)
Working Pressure Range0–10 barHandles drinking-water headers and medium-pressure disinfection
Dosing Flow Rate3 L/minHigh capacity for large nursery, sow, and finisher lines
Ratio Adjustment Range1:50 – 1:1000Direct digital entry—no mechanical sleeves or fixed 1:128 limits
Dosing AccuracyUp to 99.6%Unaffected by barn water pressure fluctuations
Interface & TelemetryDigital touchscreen + remote comm portCompatible with external pulse flow meters and SCADA
Sizing & Site Prep

Calculate Your Swine Medication Ratio, Daily Stock Volume & Bypass Plumbing

Interactive Dosing Tool

Disinfectant & Medicator Proportioning Calculator

Calculate exact chemical concentrate consumption and select the right BioFortis proportional medicator for your barn pipeline.

Concentrate Injection Rate--
Daily Chemical Requirement--
Recommended Medicator--
“Across a 10,000-sow commercial herd, even a 5% medication dosing error burns through the cost of multiple precision medicators every year—locking every milliliter to 99.6% digital accuracy is lean swine production.”
BioFortis Swine Health & Dosing Engineering
Common Field Problems

Four Swine Water Medication Failures BioFortis P14 Eliminates

Field Problem

Pressure Swings Skewing Mechanical Pistons

How BioFortis Solves It

Electronic pulse-meter closed loop maintains up to 99.6% accuracy regardless of line pressure changes.

Field Problem

Fixed 1:128 Ratio Stock-Mixing Mistakes

How BioFortis Solves It

Digital touchscreen accepts any ratio from 1:50 to 1:1000 directly without manual math.

Field Problem

Acid & Disinfectant Corrosion of Seals

How BioFortis Solves It

Chemical-resistant wetted components handle both drinking-water organic acids and 0–10 bar disinfection.

Field Problem

Zero Visibility into Night-Shift Dosing

How BioFortis Solves It

Remote communication port feeds verifiable consumption logs directly to central farm SCADA.

Delivery Process

How BioFortis Calibrates, Ships & Supports Your P14 Inline Medicator

01

Line & Flow Audit

Verify barn pipe diameter, peak water flow, and medication/acid list.

Day 1
02

Pulse Meter Match

Pair P14 with the exact pulse-output water meter and bypass check valve.

Day 2–3
03

99.6% Factory FAT

Wet-calibrate ratio accuracy across 0–10 bar before shock-proof packing.

Week 2
04

Air / Sea Delivery

Ship compact crates via express air or consolidate in main equipment containers.

FOB / CIF
05

Touchscreen & SCADA SOP

Provide English quick-start video and remote SCADA commissioning support.

24h SLA
Field Validation: Automated Chemical Proportioning Rooms in Vietnam Swine Sites
Field Track Record

Field Validation: Automated Chemical Proportioning Rooms in Vietnam Swine Sites

BioFortis automated proportioning and chemical dosing rooms are deployed across 3 commercial swine facilities for a Leading Integrated Commercial Swine Producer in Vietnam, replacing manual mixing with repeatable, auditable dosing.

Testing & Export Docs

What Engineering Documentation Ships with Every P14 Water Medicator?

DOC-01

99.6% Calibration FAT Sheet

Factory wet-test certificate verifying accuracy across 0–10 bar.

Included
DOC-02

Bypass & Pulse-Meter Schematic

Clear plumbing loop, check-valve placement, and remote comm wiring diagram.

Included
DOC-03

English Touchscreen & Flush SOP

Ratio programming, post-treatment flushing, and preventive maintenance guide.

Included
DOC-04

Export Docs & Seal Spare BOM

Customs pack plus recommended O-ring, check-valve, and suction strainer kit.

Included
10 Common Questions

Frequently Asked Questions About the P14 Medium-Pressure Inline Water Medicator

01How does BioFortis P14 maintain 99.6% accuracy when barn water pressure fluctuates?
Unlike mechanical water-driven pistons that slow down or stall as line pressure changes, P14 tracks actual water volume via an external pulse water meter and drives a 0–10 bar electronic metering head—keeping concentration locked up to 99.6%.
02Can one P14 medicator handle both drinking-water antibiotics and barn disinfection?
Yes. Its 0–10 bar operating range, up to 99.6% precision, and chemical-resistant wetted components handle therapeutic antibiotics, electrolytes, organic acids, and pressurized disinfection lines seamlessly.
03Why is touchscreen 1:50–1:1000 ratio entry better than fixed 1:128 mechanical medicators?
With fixed 1:128 pumps, staff must recalculate stock-bucket concentrations manually every time a veterinarian prescribes a different dilution. P14 lets staff type the exact ratio (1:50 to 1:1000) directly on the touchscreen in seconds.
04How does P14 connect to an external pulse water meter and farm SCADA?
P14 features a dedicated pulse-input terminal that accepts standard reed-switch or Hall-effect pulse water meters, plus a remote communication port to transmit dosing status and volume totals to central SCADA.
05When should a pig farm choose P14 vs. P13 (High-Pressure) or P15 (Tank Batch)?
Choose P14 for 0–10 bar pressurized drinking-water lines and medium-pressure disinfection; choose P13 for 0.5–10 MPa (custom 25 MPa) high-pressure wash manifolds; choose P15 for non-pressurized disinfection storage tank refills.
06What maximum main-line water flow can P14's 3 L/min dosing output support?
At a 1:100 (1%) dilution ratio, 3 L/min of chemical output supports up to 300 L/min (18 m³/h) of main-line water flow—easily covering large commercial sow, nursery, and finisher buildings.
07Does P14 work accurately at very low nursery piglet drinking flows?
Yes. Paired with an appropriately sized low-start pulse water meter, P14 accurately meters small micro-doses even when newly weaned piglets are drinking minimal volumes.
08How do we prevent antibiotic powders or organic acids from clogging the pump head?
Always use fully dissolved stock solutions with a suction foot-valve strainer, and flush the P14 pump head with clean water for 2–3 minutes immediately after completing a medication cycle.
09Is AC 220V / 60Hz supported for Latin American or Philippine farms?
Yes. Standard units ship in AC 220V / 50Hz, and BioFortis supplies 60Hz power configurations for export regions upon order.
10Can BioFortis supply the matching pulse water meter and bypass kit together?
Yes. We can bundle the matching pulse water meter, Y-strainer, check valve, and 12-month seal spare kit in the same shipment so site installation is plug-and-play.
Talk to an Engineer

Request a Sizing Check & Quote for the P14 Inline Water Medicator

Tell us your barn water line diameter, peak flow rate, and number of houses to receive a P14 bypass kit and FOB/CIF quote.

Related Equipment

Direct Engineering Desk · 12-Hour Response

Request a Quote & CAD Layout

Dual-channel submission (Web3Forms + direct server backup). Share your herd scale, truck volume, or utility specs for a tailored CAD layout and FOB/CIF quotation.